Agilent 4287A RF LCR Meter1 MHz - 3 GHzData Sheet
Timing chart and measurement time (Typical)Timing chart of handler interface signal (Typical)Figure 4. Timing chart of handler interfaceTable 1. Value
11/INDEX/EOMT4 T5Ts T t Tp Tr TsTm Tp TmTs TtTmN:Sorting resultoutputInternalprocessTrigger delay time(user's setup)Meas. pointdelay time(user&ap
12OPEN/SHORT/LOADCalibrationConnect OPEN, SHORT, and LOAD standards to thedesired reference plane and measure each kind ofcalibration data. The refere
DC resistance (Rdc) measurementTrigger functionAveraging function13Measurement range 0.1 Ω to 100 ΩMeasurement resolution 1 mΩTest signal level 1 mA (
14Measurement Support FunctionsDisplayList measurement functionTest signal level monitor functionMass storageType/Size Color LCD, 8.4 inchResolution 6
15Standard conformity IEEE 488.1-1987,IEEE 488.2-1987Available functions(function code)SH1,AH1,T6,TE0,L4,LE0,SR1,RL0,PP0, DT1,DC1,C0,E2Numerical data
16Connector type 3.5-mm (female) connector(can be converted to 7-mm connector using the3.5 mm-7 mm adapter)Frequency 10 MHz ± 10 ppm (SPC)Level ≥ 0 dB
17TpTpTpTp5V0V5V0VPositive trigger signal Negative trigger signal 1 19 2 20 3 21 4 22 5 23 6
18Temperature 5 °C to 40 °CHumidity (at wet bulbtemperature ≤ 29 °C, withoutcondensation)Flexible disk drivenon-operating condition20% to 80% RHFlexib
19General CharacteristicsOther specificationsEMC European Council Directive 89/336/EECIEC 61326-1:1997+A1CISPR 11:1990 / EN 55011:1991 Group 1, Class
2SpecificationsSpecifications describe the instrument’s warranted performance over the temperature range of 5 °C to 40 °C (except as noted). Supplemen
20425.6221.6227.5162.540.658.8General CharacteristicsFigure 9. Main unit dimensions (front view, in millimeters, typical)Figure 10. Main unit dimensio
21389.743223.4214.3617.331821.0212.77221.6216.9724.2423.547.27.354.99.0389.721169.171010409.034-M4 Effective Depth 5.6General CharacteristicsFigure 11
22General CharacteristicsFurnished accessoriesOptionsOrder model/option number Description QtyAgilent 4287A RF LCR meter (main unit)
23Short device 1.0 × 0.5 mm (part number: 16191-29005)1.6 × 0.8 mm (part number: 16191-29006)2.0 × 1.25 mm (part number: 16196-29007)3.2 × 1.6 mm (par
Agilent Technologies’ Test and MeasurementSupport, Services, and AssistanceAgilent Technologies aims to maximize the valueyou receive, while minimizin
Impedance parameters |Z|, |Y|, Ls, Lp, Cs, Cp, Rs, Rp, X, G, B, D, Q, θz[°],θz [rad], θy[°], θy [rad](A maximum of four parameters can be displayed at
RangeCable length: 1mPower (when 50 Ω LOAD isconnected to the test port)–40 dBm to 1 dBm (Frequency ≤ 1 GHz)≥ –40 dBm to 0 dBm (Frequency > 1 GHz
Temperature 23 ± 5 °CAccuracy-specified plane 7-mm connector of 3.5-mm-7-mm adapter connected to 3.5-mm terminal of test headsWhen OPEN/SHORT/LOADcali
q [rad]L, C, X, B [%]R, G [%]DQDx =Measurement value of DQx =Measurement value of QEa =(Within ± 5 °C from the calibration temperature.Measurement acc
Frequency > 1.8 GHz,≤ 3 GHz± 5 [%]Oscillator level < –33dBmFrequency ≥ 1 MHz,≤ 100 MHz± 1 [%]Frequency > 100 MHz,≤ 500 MHz± 1.2 [%]Frequency
10pH1mH1pF10pF10ƒF1M 10M 100M 1G 3G Frequency [Hz]100ƒF100nH10nH1nH100pH100nF1µF1µH100µH10µH1
10pH1mH1pF10pF10ƒF1M 10M 100M 1G 3G Frequency [Hz]100ƒF100nH10nH1nH100pH100nF1µF1µH100µH10µH1
Comentários a estes Manuais