Vista de página 118
Source Intra-Pair Skew Tests 12
U7232A DisplayPort Compliance Testing Notes 119
PASS Condition
Intra- pair Skew 30 ps
Test R ef er en ce s
See Test 3.5: in the DisplayPort- Compliance Test Specification Version 1.
Rise-Fall Mismatch Edge Sets the number of edges measured for the rise-fall mismatch test.
Upper Threshold (Debug
only)
Sets the upper threshold used to make a rise time or fall time
measurement.
Lower Threshold (Debug
only)
Sets the lower threshold used to make a rise time or fall time
measurement.
Intra-pair Skew
Intra-pair Edge Sets the number of edges measured for the intra-pair skew test.
AC Common Mode
AC Common Edge Sets the number of edges measured for the AC common mode test.
Table 13 Test Configuration Options
Configuration Option Description
Vista de página 118