Table 42 Environment Variables for Trap-Triggered Scripts
Variable Definition
$TRAPTYPE One of these values: Rising, Falling, or Match.
$AGENT Name of the data source that sent the trap.
$ALARMROW Row in the alarm table of the triggered alarm.
$OBJECT Object identifier of the monitored object.
$THRESHOLD Alarm threshold value that was crossed.
$VALUE Measured value for the monitored object.
$SEVERITY Severity of the alarm.
$COMMUNITY Community name used when communicating with the
agent.
$DESCRIPTION Description of the triggered alarm.