Agilent Technologies 8922M Guia do Utilizador Página 72

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 94
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 71
58 Chapter5
Remote operation
HSCSD Subsystem GPIB Commands
HSCSd:SLAVe:DOWNlink:AMPLitude:OFFSet
Description This sets the amplitude offset (in dBs) of the slave timeslot, using the
master’s downlink amplitude as a reference.
The resulting amplitude must lie within the normal downlink power
range. If not, the error Disallowed due to pulse mod configuration
is produced, and the setting is ignored.
Syntax HSCSd:SLAVe:DOWNlink:AMPLitude?
HSCSd:SLAVe:DOWNlink:AMPLitude:OFFSet <real>
Command options
Type floating point
Units: dB only
Limits -100.0 thru 100.0
Default 0.0