Agilent Technologies U1242A Manual de Serviço Página 1

Consulte online ou descarregue Manual de Serviço para Multímetros Agilent Technologies U1242A. Agilent Technologies U1242A Technical data Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 0
Agilent Technologies
Agilent U1241A and
U1242A
Handheld Digital
Multimeters
User’s and Service Guide
Vista de página 0
1 2 3 4 5 6 ... 84 85

Resumo do Conteúdo

Página 1 - Multimeters

Agilent TechnologiesAgilent U1241A and U1242AHandheld Digital MultimetersUser’s and Service Guide

Página 2

X U1241A/U1242A User’s and Service GuideDeclaration of Conformity (DoC)The Declaration of Conformity (DoC) for this instrument is available on the We

Página 3 - Safety Symbols

U1241A/U1242A User’s and Service Guide XIContents1 Getting StartedIntroduction 2Checking the Shipping Contents 3The Front Panel at a Glance 4Adjusting

Página 4 - General Safety Information

XII U1241A/U1242A User’s and Service GuideRefresh Hold 19NULL (Relative) 19Data Logging (U1242A) 20Manual Logging 21Interval Logging 21Reviewing Logge

Página 5

U1241A/U1242A User’s and Service Guide XIIIRecommended Test Equipment 38Basic Operating Test 39Backlight Test 39Testing the Display 39Input-A Terminal

Página 6 - Environment Conditions

XIV U1241A/U1242A User’s and Service GuideHarmonic Ratio Specifications 62Frequency Specifications 63Frequency Sensitivity During Voltage Measurement[

Página 7 - Regulatory Markings

1Agilent TechnologiesU1241A and U1242A Handheld Digital MultimetersUser’s and Service Guide1Getting Started Introduction 2 Checking the Shipping Conte

Página 8 - 2002/96/EC

2 U1241A/U1242A User’s and Service Guide1Getting Started IntroductionThe handheld digital multimeters’ key features are:• DC, AC voltage and current

Página 9 - In This Guide…

Getting Started 1U1241A/U1242A User’s and Service Guide 3Checking the Shipping ContentsVerify that you have received the following items for the sta

Página 10

4 U1241A/U1242A User’s and Service Guide1Getting Started The Front Panel at a GlanceFigure 1-1 Front panel of a U1241A and U1242A handheld digital mu

Página 11 - Contents

Getting Started 1U1241A/U1242A User’s and Service Guide 5The Annunciator at a GlanceTo view the full display, press and hold while turning the rot

Página 12 - 4 Service and Maintenance

II U1241A/U1242A User’s and Service GuideNotices© Agilent Technologies, Inc., 2007 – 2012No part of this manual may be reproduced in any form or by a

Página 13

6 U1241A/U1242A User’s and Service Guide1Getting Started Analog Bar GraphWhen frequency is indicated on the primary display during voltage or cur-ren

Página 14

Getting Started 1U1241A/U1242A User’s and Service Guide 7Table 1 - 4 Keypad descriptions and functionsTable 1 - 5 Features that can be accessed thro

Página 15 - Getting Started

8 U1241A/U1242A User’s and Service Guide1Getting Started The Input Terminal at a GlanceFigure 1-5 Input terminal of a U1242A handheld digital multime

Página 16 - Introduction

9Agilent TechnologiesU1241A and U1242A Handheld Digital MultimeterUser’s and Service Guide2Features and FunctionsMeasuring Voltage 10Measuring Current

Página 17

10 U1241A/U1242A User’s and Service Guide2 Features and Functions Measuring VoltageMeasuring DC Voltage

Página 18 - Adjusting Tilt Stand

Features and Functions 2U1241A/U1242A User’s and Service Guide 11Measuring Current (< 440 mA)Measuring % Scale of 4 – 20 mA NOTEIf the measured v

Página 19 - The Annunciator at a Glance

12 U1241A/U1242A User’s and Service Guide2 Features and Functions Measuring Frequency Measuring Resistance and Testing ContinuityCAUTIONDisconnect

Página 20 - Analog Bar Graph

Features and Functions 2U1241A/U1242A User’s and Service Guide 13Testing DiodesNOTEPress button to select measurement range from 1 kW to 100 MW.CA

Página 21 - Getting Started 1

14 U1241A/U1242A User’s and Service Guide2 Features and Functions Measuring CapacitanceMeasuring TemperatureCAUTIONDisconnect circuit power and di

Página 22 - 1Getting Started

Features and Functions 2U1241A/U1242A User’s and Service Guide 15If you are working in a varied environment, where ambient temperature is not consta

Página 23 - Features and Functions

U1241A/U1242A User’s and Service Guide IIISafety SymbolsThe following symbols on the instrument and in the documentation indicate precautions which mu

Página 24 - Measuring Voltage

16 U1241A/U1242A User’s and Service Guide2 Features and Functions Measuring Harmonic Ratio (U1242A)Using Switch CounterPress at positionHarmonic

Página 25

Features and Functions 2U1241A/U1242A User’s and Service Guide 171 Remove the power on the contacts or switch before measured. 2 Press at positi

Página 26 - Measuring Frequency

18 U1241A/U1242A User’s and Service Guide2 Features and Functions MINMAX Recording1 Press for more than one second to enter MINMAX Recording mod

Página 27 - Forward bias

Features and Functions 2U1241A/U1242A User’s and Service Guide 19Refresh HoldUsers are required to activate the Refresh Hold in the setup mode.1 Pre

Página 28 - Measuring Temperature

20 U1241A/U1242A User’s and Service Guide2 Features and Functions Data Logging (U1242A)The data logging function stores the data in non- volatile

Página 29 - T1T2 (U1242A)

Features and Functions 2U1241A/U1242A User’s and Service Guide 21Manual LoggingTo enable the Hand (manual) logging function, select the Hand logging

Página 30 - Using Switch Counter

22 U1241A/U1242A User’s and Service Guide2 Features and Functions Figure 2-7 Interval logging displayReviewing Logged Data1 Press (View) for mor

Página 31

Features and Functions 2U1241A/U1242A User’s and Service Guide 23Scanning Temperature Measurement (U1242A)This scanning temperature measurement func

Página 32 - Data Hold (Trigger Hold)

24 U1241A/U1242A User’s and Service Guide2 Features and Functions Alerts and Warning During Measurement Overload AlertThe meter provides an overlo

Página 33 - NULL (Relative)

25Agilent TechnologiesU1241A and U1242A Handheld Digital MultimeterUser’s and Service Guide3Default Setting ConfigurationsSetting Configurations 26Thi

Página 34 - Data Logging (U1242A)

IV U1241A/U1242A User’s and Service GuideGeneral Safety InformationThe following general safety precautions must be observed during all phases of ope

Página 35 - Interval Logging

26 U1241A/U1242A User’s and Service Guide3 Default Setting ConfigurationsSetting Configurations1 Turn meter OFF. 2 From OFF position, press and hold

Página 36 - Removing Logged Data

Default Setting Configurations 3U1241A/U1242A User’s and Service Guide 27Table 3 - 9 Available setting options in Setup modeMenu item Available settin

Página 37 - Checking Battery Capacity

28 U1241A/U1242A User’s and Service Guide3 Default Setting Configurations[1] To activate the meter after it has auto power off, press any button to r

Página 38 - Input-mA Warning Alert

29Agilent TechnologiesU1241A and U1242A Handheld Digital MultimeterUser’s and Service Guide4Service and MaintenanceGeneral Maintenance 30Battery Repla

Página 39 - Agilent Technologies

30 U1241A/U1242A User’s and Service Guide4 Service and Maintenance General MaintenanceBesides the above hazard, dirt or moisture in the terminals can

Página 40 - Setting Configurations

Service and Maintenance 4U1241A/U1242A User’s and Service Guide 313 Lift and remove the battery cover to the direction of screw.4 Replace the spe

Página 41

32 U1241A/U1242A User’s and Service Guide4 Service and Maintenance 3 Gently remove the defective Fuse 1 by prying one end of the fuse and removing it

Página 42

Service and Maintenance 4U1241A/U1242A User’s and Service Guide 338 Ensure that the rotary switch position is aligned with the align marking on t

Página 43 - Service and Maintenance

34 U1241A/U1242A User’s and Service Guide4 Service and Maintenance Returning Instrument for ServiceBefore shipping your instrument for repair or repl

Página 44 - Battery Replacement

35Agilent TechnologiesU1241A and U1242A Handheld Digital MultimeterUser’s and Service Guide5Performance Tests and CalibrationCalibration Overview 36Re

Página 45 - Fuse Replacement

U1241A/U1242A User’s and Service Guide VWARNING• Do not use repaired fuses or short-circuited fuse-holders. For continued protection against fire, rep

Página 46 - Rotary Switch

36 U1241A/U1242A User’s and Service Guide5 Performance Tests and CalibrationCalibration OverviewClosed-case Electronic CalibrationThe meter features

Página 47 - Troubleshooting

Performance Tests and Calibration 5U1241A/U1242A User’s and Service Guide 37Adjustment is RecommendedSpecifications are only guaranteed within the per

Página 48

38 U1241A/U1242A User’s and Service Guide5 Performance Tests and CalibrationRecommended Test EquipmentThe test equipment recommended for the performa

Página 49

Performance Tests and Calibration 5U1241A/U1242A User’s and Service Guide 39Basic Operating TestBasic Operating Test is used to test the basic operabi

Página 50 - Calibration Overview

40 U1241A/U1242A User’s and Service Guide5 Performance Tests and CalibrationInput-A Terminal TestThis test determines if the input warning of the A c

Página 51 - Adjustment is Recommended

Performance Tests and Calibration 5U1241A/U1242A User’s and Service Guide 41Test ConsiderationsError may be induced by AC signals that present on the

Página 52 - Recommended Test Equipment

42 U1241A/U1242A User’s and Service Guide5 Performance Tests and CalibrationInput ConnectionsTest connections to the meter are best accomplished usin

Página 53 - Basic Operating Test

Performance Tests and Calibration 5U1241A/U1242A User’s and Service Guide 43Table 5 - 13 Verification TestsStep Test Function Range 5520A Output Err

Página 54 - Calibration Process

44 U1241A/U1242A User’s and Service Guide5 Performance Tests and CalibrationStep Test Function Range 5520A Output Error from nominal 1 yearU1241A U

Página 55 - Test Considerations

Performance Tests and Calibration 5U1241A/U1242A User’s and Service Guide 45[1] The accuracy of 1 kW and 10 kW are specified after Math Null, that is

Página 56 - Input Connections

VI U1241A/U1242A User’s and Service GuideEnvironment ConditionsThis instrument is designed for indoor in the area with low condensation and use with

Página 57 - U1241A U1242A

46 U1241A/U1242A User’s and Service Guide5 Performance Tests and CalibrationCalibration SecurityThe calibration security code prevents accidental or

Página 58

Performance Tests and Calibration 5U1241A/U1242A User’s and Service Guide 47“E02” on the secondary display for approximately 3 seconds and return to t

Página 59 - T2 function

48 U1241A/U1242A User’s and Service Guide5 Performance Tests and Calibration6 Set the code, same as the last 4 digit serial number of the meter. Pres

Página 60 - Calibration Security

Performance Tests and Calibration 5U1241A/U1242A User’s and Service Guide 49Adjustment Considerations1 Allow the meter to warm up and stabilize for fi

Página 61

50 U1241A/U1242A User’s and Service Guide5 Performance Tests and CalibrationValid Adjustment Input Values Adjustment can be accomplished using the fo

Página 62 - Entering Adjustment Values

Performance Tests and Calibration 5U1241A/U1242A User’s and Service Guide 51Calibration Adjustments1 Turn the rotary switch to Test Function position,

Página 63 - Adjustment Considerations

52 U1241A/U1242A User’s and Service Guide5 Performance Tests and Calibration9 Turn the rotary switch to the next function according to the Test Funct

Página 64

Performance Tests and Calibration 5U1241A/U1242A User’s and Service Guide 53Step Test Function Cal Range Input Cal ItemU1241A U1242A3 Turn the rotary

Página 65 - Calibration Adjustments

54 U1241A/U1242A User’s and Service Guide5 Performance Tests and CalibrationStep Test Function Cal Range Input Cal ItemU1241A U1242A6 Turn the rotar

Página 66

Performance Tests and Calibration 5U1241A/U1242A User’s and Service Guide 55Exiting Adjustment Mode1 Remove all shorting plugs and connectors from the

Página 67

U1241A/U1242A User’s and Service Guide VIIRegulatory MarkingsThe CE mark is a registered trademark of the European Community.This CE mark shows that t

Página 68

56 U1241A/U1242A User’s and Service Guide5 Performance Tests and CalibrationCalibration Count The meter provides the calibration count information fo

Página 69 - Exiting Adjustment Mode

57Agilent TechnologiesU1241A and U1242A Handheld Digital MultimeterUser’s and Service Guide6Specifications and Characteristics DC Specifications 58AC

Página 70 - Calibration Errors

58 U1241A/U1242A User’s and Service Guide6 Specifications and CharacteristicsDC SpecificationsTable 6 - 17 DC specifications with accuracy of ± (% of

Página 71

Specifications and Characteristics 6U1241A/U1242A User’s and Service Guide 59AC SpecificationsTable 6 - 18 AC specifications with accuracy of ± (% of

Página 72 - DC Specifications

60 U1241A/U1242A User’s and Service Guide6 Specifications and CharacteristicsResistance SpecificationsTable 6 - 19 Resistance specifications with acc

Página 73 - AC Specifications

Specifications and Characteristics 6U1241A/U1242A User’s and Service Guide 61Temperature SpecificationsTable 6 - 21 Temperature specifications with a

Página 74 - Resistance Specifications

62 U1241A/U1242A User’s and Service Guide6 Specifications and CharacteristicsCapacitance SpecificationsTable 6 - 22 Capacitance specifications with a

Página 75 - Temperature Specifications

Specifications and Characteristics 6U1241A/U1242A User’s and Service Guide 63[2] Pure sinusoidal waveforms without harmonics have a harmonics ratio o

Página 76 - Harmonic Ratio Specifications

64 U1241A/U1242A User’s and Service Guide6 Specifications and CharacteristicsFrequency SpecificationsTable 6 - 24 Frequency specifications with accur

Página 77

Specifications and Characteristics 6U1241A/U1242A User’s and Service Guide 65Operating SpecificationsTable 6 - 25 Measuring rate of U1241A and U1242A

Página 78 - Frequency Specifications

VIII U1241A/U1242A User’s and Service GuideWaste Electrical and Electronic Equipment (WEEE) Directive 2002/96/ECThis instrument complies with the WEE

Página 79 - Operating Specifications

66 U1241A/U1242A User’s and Service Guide6 Specifications and CharacteristicsGeneral CharacteristicsTable 6 - 26 General characteristics of U1241A an

Página 80 - General Characteristics

Specifications and Characteristics 6U1241A/U1242A User’s and Service Guide 67Weight• 450 g with batteries• 400 g without batteriesWarranty • Please r

Página 81

68 U1241A/U1242A User’s and Service Guide6 Specifications and Characteristics

Página 82

U1241A/U1242A User’s and Service Guide 67 IndexIndexAAC, 59accuracy, 60adjustments, VAltitude, VI, 65Bbattery, IVCCalibrationOverview, 36calibrator, 6

Página 83

68 U1241A/U1242A User’s and Service GuideIndexStorage, VIsymbols, IIITtagsparagraphs, 2, 10, 58Temperature, 60Te s tConsiderations, 40Equipment, 38te

Página 84

www.agilent.comAgilent Technologies© Agilent Technologies, Inc. 2007 – 2012Printed in MalaysiaSeventh Edition, May 4, 2012U1241-90003Contact usTo obta

Página 85

U1241A/U1242A User’s and Service Guide IXIn This Guide…1Getting Started Chapter 1 introduces key features and steps to get started with a U1241A o

Comentários a estes Manuais

Sem comentários