RF Power Measurements
Frequency Range: 30 MHz to 1 GHz, 1.7 to 2.0 GHz
Figure 2. Accuracy
Measurement Range RF IN/OUT:
2
100 MHz <f
c
<2.0 GHz:
4 mW to 100 W continuous, temperatures <40° C,
75 W continuous, for temperatures <55° C
30 MHz <f
c
<100 MHz: 4 mW to 1 W continuous
Supplemental Characteristics
Resolution: 3 digits (Example: Resolution of 10 mW for powers
<10 W and >1 W)
FM Measurement
Frequency Range: 5 MHz to 1 GHz (usable to 400 kHz),
and 1.7 to 2.0 GHz
Deviation: 20 Hz to 75 kHz
Sensitivity: 4 µV for 12 dB SINAD, (30 kHz IF BW,
high sensitivity mode, 0.3 to 3 kHz BW)
Typically: < 2 µV (12 dB SINAD, f
c
>10 MHz)
Accuracy: ±4% of reading plus residual FM and noise contribution
(20 Hz to 25 kHz rates, deviation < 25 kHz, 230 kHz IF BW)
Bandwidth (3 dB): 20 Hz to 70 kHz
THD + Noise: <1% rms, (for deviation >5 kHz and at a rate of
1 kHz in a 0.3 to 3 kHz BW, 230 kHz IF BW)
Input Level Range for Specified Accuracy:
–6 to +50 dBm at RF IN/OUT
–44 to +12 dBm at ANTENNA IN
Residual FM and Noise (0.3 to 3 kHz, rms):
<7 Hz, for f
c
<1000 MHz
<14 Hz, for 1.7 <f
c
<2.0 GHz
Supplemental Characteristics
Resolution: 1 Hz, f <10 kHz ; 10 Hz, f >10 kHz
AM Measurement
Frequency Range: 10 MHz to 1 GHz (usable to 400 kHz), 1.7 to 2.0 GHz
Depth: 0 to 95%
Input Level Range (levels in PEP):
–6 to +52 dBm at RF IN/OUT
–44 to +14 dBm at ANTENNA IN
Supplemental Characteristics
Accuracy: ±5% of reading ±1.5 % AM, ( 50 Hz to 10 kHz rates,
modulation <80%)
THD + Noise: <2% rms for modulation <80% AM,
(at 1 kHz rate in a 0.3 to 3 kHz bandwidth)
Residual AM: <0.2% in a 0.3 to 3 kHz bandwidth
Resolution: 0.1%
Spectrum Analyzer Specifications
Frequency Range: 400 kHz to 1 GHz, 1.4 to 2.0 GHz
Frequency Span/Resolution Bandwidth (coupled):
Span Bandwidth
<50 kHz 300 Hz
<200 kHz 1 kHz
<1.5 MHz 3 kHz
<18 MHz 30 kHz
>18 MHz 300 kHz
Span Capability:
3
Full span capability 1 GHz
Display: Log with 1, 2, and 10 dB per division
Display Range: 80 dB or 8 divisions
Reference Level Range: +50 to –50 dBm
Residual Responses: <–70 dBm (ANT IN port, no input signal,
0 dB attenuation)
Image rejection: >50 dB
Supplemental Characteristics
Non-harmonic Spurious Responses:
>65 dB down (for input signals >50 MHz, <–30 dBm),
>55 dB down (for input signals <50 MHz, <–30 dB)
Log Scale Linearity: ±2 dB, (for input levels <–30 dBm within 6
divisions of reference level
Displayed Average Noise Level: <–114 dBm, for <50 kHz span,
–50 dBm reference level
Level Accuracy (at center frequency and within 1 division of
reference level): ±2.5 dB
Tracking Generator Specifications
Tracking Generator Frequency Range: 400 kHz to 1 GHz,
1.7 to 2.0 GHz
Frequency Offset: Frequency span endpoints ± frequency offset
cannot be <400 kHz or >1 GHz in the 1 GHz band and cannot be
<1.7 GHz or >2.0 GHz in the 2 GHz band
Output Level Range: Same as signal generator, page 4
Sweep Modes: Normal and inverted
2. To achieve the specified accuracy when measuring power at the RF IN/OUT port,
the internal signal generator level must be 60 dB below the measured power or
less than –20 dBm at the Duplex port.
3. Center frequency must be <1.0 GHz or between 1.7 to 2.0 GHz
5
100%
80%
60%
40%
20%
0º C 10º C 20º C 30º C 40º C 50º C 60º C
32º F 50º C 68º C 86º C 104º C 122º C 140º C
Temperature
Relative Humidity
±(7.5% ±50 µW)
Typically ±5%
1.7 GHzf
c
2.0 GHz
±(12% ±50µW)
Typically 10%
f
c
1000 MHz
±(10% ±50 µW)
Typically ±7%