Agilent Technologies InfiniiVision 6000 Series Manual do Utilizador Página 5

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 22
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 4
5
High-voltage Passive Probes
Ideal for measuring up to 30 kV
Up to 250 MHz bandwidth
100:1 or 1000:1 attenuation
10076B high-voltage probe
The Agilent 10076B 4 kV 100:1
passive probe gives you the voltage
and bandwidth you need for making
high-voltage measurements. Its
compact design makes it easier to
probe today’s small power electronics
components and its rugged
construction means it can withstand
rough handling without breaking.
Characteristics 10076B
Bandwidth 250 MHz (–3dB)
Risetime
(calculated)
< 1.4 ns
Attenuation ratio 100:1
Input resistance 66.7 MΩ (when
terminated into
1 MΩ)
Input capacitance Approx 3 pF
Maximum input 4000 Vpk
Compensation 6-20 pF
Range
Probe readout Yes
Cable length 1.8 m
10076B passive probe
N2771A high-voltage probe
10076B derating curve
N2771A derating curve
Ordering information for Agilent
high-voltage probe
10076B High-voltage probe: includes
one retractable hook tip,
one-ground-bayonet, one
IC probing tip, one-alligator
ground lead and a
compensation screwdriver
N2771A High-voltage probe: includes
alligator ground lead,
1-sharp-probe tip
10077A Accessory kit for 10076A/B:
includes one retractable
pincher tip, one ground
lead, one insulation cap,
two measuring pins and two
colored tags
N2771A high-voltage probe
The N2771A is a 1000:1 divider
probe for the measurement of
fast high voltage signals up to
30 kV dc + peak ac, 10 kV rms.
The probe’s large size and rugged
construction provides superior
protection. The ground lead is fed
through the body of the probe and
protrudes behind the safety barrier,
keeping the ground connection
away from the high voltage. Typical
applications include PMT’s, motor
drives, high voltage switches,
magnatrons and modern projection
systems.
Characteristics for N2771A
Bandwidth 50 MHz (–3dB)
Risetime <7 ns
Attenuation ratio 1000:1
Input resistance 100 MΩ (when
terminated into
1-MΩ)
Input
capacitance
1 pF
Compensation
range
7-25 pF
Max. voltage 15 kV dc, 10 kV rms,
30 kV dc + peak ac
Operating
temperature
0°C to +50°C,
80% RH
Storage
temperature
–20°C to +70°C,
90% RH
Dimensions 2 cm (max width
of probe stem after
handle) x 33 cm
7.5 cm (max probe
widthat probe
handle) x 33 cm
Vista de página 4
1 2 3 4 5 6 7 8 9 10 ... 21 22

Comentários a estes Manuais

Sem comentários