Agilent Technologies N5230C Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Medição, teste e controlo Agilent Technologies N5230C. 2-Port PNA-L [it] Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 118
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
Technical Specifications
Agilent Technologies
PNA Series Network Analyzers
N5230A/C
Options 020/025, 120/125, 220/225, 420/425, and
520/525
(2-Port PNA-L)
Manufacturing Part Number: N5230-90016
Printed in USA
Print Date: November 9, 2010
Supersedes: August 26, 2009
© Agilent Technologies, Inc. 2004 - 2010 All rights reserved.
Vista de página 0
1 2 3 4 5 6 ... 117 118

Resumo do Conteúdo

Página 1 - Technical Specifications

Technical SpecificationsAgilent TechnologiesPNA Series Network AnalyzersN5230A/COptions 020/025, 120/125, 220/225, 420/425, and 520/525 (2-Port PNA-L)

Página 2 - Documentation Warranty

6 Table 2. Extended Dynamic Range1 Description Specification (dB) at Direct Receiver Access Input Typical (dB) at Direct Receiver Access Input Opti

Página 4

97 Dynamic Accuracy, 40 - 50 GHz, Option 520 or 525

Página 5 - N5230-90016, Rev. 2010-11-09

98 a Dynamic accuracy is verified with the following measurements: • compression over frequency • IF linearity at a single frequency of 1.195 G

Página 6

99Table 19. Test Port Input (Group Delay)a Description Specification Supplemental Information (typ.) Aperture (selectable) (frequency span)/(numb

Página 7 - Definitions

100General Information Table 20. Miscellaneous Information Description Specification Supplemental Information System IF Bandwidth Range Option 020

Página 8 - Table 1. System Dynamic Range

101Table 22. Rear Panel Information Description Supplemental Information Trigger Inputs/Outputs BNC(f), TTL/CMOS compatible 10 MHz Reference In Con

Página 9

102 Table 22. Rear Panel Information (Continued) Description Supplemental Information LAN 10/100BaseT Ethernet, 8-pin configuration; auto selects

Página 10

103Measurement Throughput Summary Table 24. Typical Cycle Timea (ms) for Measurement Completion Description Typical Number of Points 201 401 80

Página 11

104Table 25. (Options 020/025, 120/125, only) Cycle Time vs IF Bandwidth Applies to the Preset condition (201 points, correction off) except for the

Página 12

105 Table 26. (Options 220/225, 420/425, 520/525 only) Cycle Time vs IF Bandwidth Applies to the Preset condition (201 points, correction off) excep

Página 13

7N5230A/C Corrected System Performance with 3.5mm Connectors Options 220/225, 420/425, 520/525: From 10 MHz to 45 MHz, performance is characterized a

Página 14

106Table 27. (Options 020/025, 120/125, only) Cycle Time vs Number of Points Applies to the Preset condition (correction off) except for the followin

Página 15

107Table 28. (Options 220/225, 420/425, 520/525 only) Cycle Time vs Number of Points Applies to the Preset condition (correction off) except for the

Página 16

108Table 29. Data Transfer Time (ms) Description Typical Number of Points 201 401 1601 16,001 SCPI over GPIB (program executed on external PC)

Página 17

109Specifications: Front-Panel Jumpers ⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯ Model N5230A/C Options 025, 125, 225, 425, and 525 ⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯

Página 18

110Table 32: Reference Outputs (Reference 1 Source Out, Reference 2 Source Out) @ Max Specified Output Power Description Specification Typical

Página 19

111Table 34: Coupler Inputs (Port 1 Cplr Thru, Port 2 Cplr Thru) Insertion Loss of Coupler Thru Description Specification Typical Option 025,

Página 20

112Table 35: Coupler Outputs (Port 1 Cplr Arm, Port 2 Cplr Arm) Description Specification Typical Option 025, 125 Option 225 Option 425, 525

Página 21

113Test Set Block Diagrams N5230A/C Option020, or 120, or 220, or 420, or 520 (Standard Test Set and Standard Power Range)

Página 22

114N5230A/C Option025, or 125, or 225, or 425, or 525 (Configurable Test Set and Extended Power Range) Item Description Item Description

Página 23

8 NOTE: The following graphs also apply to the “C” model of the analyzer. Transmission Uncertainty (Specifications)

Página 24

9 Reflection Uncertainty (Specifications)

Página 25

10 Table 4. 85052B Calibration Kit N5230A/C- Option 025/125 (Configurable Test Set and Extended Power Range) Applies to the N5230A/C Option 025/125

Página 26

11 NOTE: The following graphs also apply to the “C” model of the analyzer. Transmission Uncertainty (Specifications)

Página 27

12 Reflection Uncertainty (Specifications)

Página 28

13 Table 5. 85052B Calibration Kit N5230A/C- Option 220 (Standard Test Set and Standard Power Range) Applies to the, N5230A/C Option 220 analyzers,

Página 29 - Description

14 NOTE: The following graphs also apply to the “C” model of the analyzer. Transmission Uncertainty (Specifications)

Página 30

15 Reflection Uncertainty (Specifications)

Página 31

Documentation WarrantyTHE MATERIAL CONTAINED IN THIS DOCUMENT IS PROVIDED "AS IS," AND IS SUBJECT TO BEING CHANGED, WITHOUT NOTICE, IN FUTU

Página 32

16 Table 6. 85052B Calibration Kit N5230A/C- Option 225 (Configurable Test Set and Extended Power Range) Applies to the, N5230A/C Option225 analyze

Página 33

17NOTE: The following graphs also apply to the “C” model of the analyzer. Transmission Uncertainty (Specifications)

Página 34

18 Reflection Uncertainty (Specifications)

Página 35

19⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯ N4691B Electronic Calibration (ECal) Module ⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯ Table 7. N469

Página 36

20 NOTE: The following graphs also apply to the “C” model of the analyzer. Transmission Uncertainty (Specifications)

Página 37

21 Reflection Uncertainty (Specifications)

Página 38

22 Table 8. N4691B Electronic Calibration Module N5230A/C- Option 225 (Configurable Test Set and Extended Power Range) Applies to the, N5230A/C Opti

Página 39

23 NOTE: The following graphs also apply to the “C” model of the analyzer. Transmission Uncertainty (Specifications)

Página 40

24 Reflection Uncertainty (Specifications)

Página 41 - 85032B Calibration Kit

25 N5230A/C Corrected System Performance with 2.4mm Connectors ⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯ 85056A Calibration Kit: ⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯

Página 42

Contacting AgilentAssistance with test and measurement needs and information on finding a local Agilent office are available on the Web at:http://www.

Página 43

26 NOTE: The following graphs also apply to the “C” model of the analyzer. Transmission Uncertainty (Specifications)

Página 44

27 Reflection Uncertainty (Specifications)

Página 45

28 Table 10. 85056A Calibration Kit N5230A/C- Option 425 or 525 (Configurable Test Set and Extended Power Range) Applies to the N5230A/C Option425 o

Página 46

29NOTE: The following graphs also apply to the “C” model of the analyzer. Transmission Uncertainty (Specifications)

Página 47

30 Reflection Uncertainty (Specifications)

Página 48

31 ⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯ N4693A Electronic Calibration Module ⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯ Table 11. N4693A El

Página 49

32 NOTE: The following graphs also apply to the “C” model of the analyzer. Transmission Uncertainty (Specifications)

Página 50 - Table 16. Test Port Output

33 Reflection Uncertainty (Specifications)

Página 51 - (Continued)

34 Table 12. N4693A Electronic Calibration Module N5230A/C- Option 425 or 525 (Configurable Test Set and Extended Power Range) Applies to the N5230A

Página 52

35NOTE: The following graphs also apply to the “C” model of the analyzer. Transmission Uncertainty (Specifications)

Página 53

This page intentionally left blank.

Página 54

36 Reflection Uncertainty (Specifications)

Página 55

37N5230A/CCorrected System Performance with Type-N Connectors ⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯ 85032B Calibration Kit ⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯⎯

Página 56

38 NOTE: The following graphs also apply to the “C” model of the analyzer. Transmission Uncertainty (Specifications)

Página 57 - Table 17. Test Port Input

39 Reflection Uncertainty (Specifications)

Página 58

40 Table 14. 85032B Calibration Kit N5230A/C- Option 025 (Configurable Test Set and Extended Power Range) Applies to the, N5230A/C Option 025 analyz

Página 59

41NOTE: The following graphs also apply to the “C” model of the analyzer. Transmission Uncertainty (Specifications)

Página 60

42 NOTE: The following graphs also apply to the “C” model of the analyzer. Reflection Uncertainty (Specifications)

Página 61

43 Table 15. Uncorrected System Performance Description Specifications Typical Options 020, 025, 120, 125 Options 220, 225 Options420, 520Options

Página 62

44 Table 15. Uncorrected System Performance (Continued) Options 020, 025, 120, 125 Options 220, 225 Options420, 425 Options520, 525Options020, 02

Página 63

45 Table 15. Uncorrected System Performance (Continued) Description Specifications Typical Options 020, 025, 120, 125 Options 220, 225 Opti

Página 64

1Technical Specifications for the N5230A/C N5230-90016, Rev. 2010-11-09 Options 020/025, 120/125, 220/225, 420/425, or 520/525 (2-Port PNA-L) Defini

Página 65

46 Table 16. Test Port Output1 Specifications Typicals Options 020, 025 Options 120, 125 Options 220, 225 Options 420, 425 Options 520, 525

Página 66

47 Table 16. Test Port Output1 (Continued) Specifications Typical Options 020, 025, 120, 125 Options 220, 225 Options 420, 425 O

Página 67

48 Table 16. Test Port Output1 (Continued) Specifications Typical Options 020, 120 Options 025, 125 Options 220, 225 Option 420 Optio

Página 68 - Options 020, 025, 120, 125

49 Table 16. Test Port Output1 (Continued) Specifications Typical Options 020, 120 Options 025, 125 Options 220, 225 Option 420 Option

Página 69

50 Table 16. Test Port Output1 (Continued) Specifications Typical Option 020, 120 Option 025, 125 Option 220 Option 225 Option 420, 520

Página 70

51 Table 16. Test Port Output1 (Continued) Description Specifications Typical -- Options 020, 025, 120, 125 Options 220, 225, 420, 425, 520,

Página 71

52 Table 16. Test Port Output1 (Continued) Description Specifications Typicals -- Options 020, 025, 120, 125, 220, 225, 420, 520, 425, 525 No

Página 72

53 Table 17. Test Port Input Description Specification Typical Options 020, 025, 120, 125 Options 220, 225 Options 420, 425 Options 520, 5

Página 73

54 Table 17. Test Port Input (Continued) Description Specification Typical Options 020, 025, 120, 125 Options 220, 225 Options 420, 425 Op

Página 74

55 Table 17. Test Port Input (Continued) Description Specification Typical Options 025, 125 Options 225 Options 425 Options 525 Option

Página 75 - Options 220, 225

2 Table 22. Rear Panel Information...101 Table 23. Analyzer Dimensi

Página 76

56 Table 17. Test Port Input (Continued) Description Specification Typical Options 025, 125 Options 225 Options 425 Options 525 Optio

Página 77

57 Table 17. Test Port Input (Continued) Description Specification Typical Options 220, 225 Options 420, 520 Options 425, 525 Options 220,

Página 78

58 Table 17. Test Port Input (Continued) Description Specification Typical Options 020, 120, 025, 125 Test Port Compression - 0.1 dB Pow

Página 79

59 Table 17. Test Port Input (Continued) Trace Noise Magnitude6 1 kHz IF bandwidth, ratioed measurement, nominal power at test port. 300 kHz to 10

Página 80

60 Table 17. Test Port Input (Continued) Specification Typical Options 020, 120, 025, 125 Options 020, 120, 025, 125 Trace Noise Magnitude6 (c

Página 81

61 Table 17. Test Port Input (Continued) Description Specification Technical Options 020, 120, 025, 125 Options 020, 120, 025, 125 Trace Noise

Página 82

62 Table 17. Test Port Input (Continued) Description Specification Typical -- -- -- -- Option 020, 025, 120, 125 Option 220, 225 Options 4

Página 83

63 Table 17. Test Port Input (Continued) Description Specifications Typical Options 020, 120 Option 220 Options 420, 520 Options 025, 125

Página 84

64 Table 18. Dynamic Accuracy (Specificationa) Accuracy of the test port input power reading relative to the reference input power level. NOTE: The

Página 85 - Options 420, 425, 520, 525

65 Dynamic Accuracy, 1 MHz- 10 MHz, Option 020, 025, 120, or 125

Página 86

3Definitions All specifications and characteristics apply over a 25 °C ±5 °C range (unless otherwise stated) and 90 minutes after the instrument has

Página 87

66 Dynamic Accuracy, 10 MHz- 1 GHz, Option 020, 025, 120, or 125

Página 88

67 Dynamic Accuracy, 1 - 8 GHz, Option 020, 025, 120, or 125

Página 89

68 Dynamic Accuracy, 8 - 10.5 GHz, Option 120 or 125

Página 90

69 Dynamic Accuracy, 10.5 - 12.5 GHz, Option 120 or 125

Página 91

70 Dynamic Accuracy, 12.5 - 13.5 GHz, Option 120 or 125

Página 92

71 Options 220, 225 Dynamic Accuracy, 0.045 GHz, Option 220 or 225

Página 94

73 Dynamic Accuracy, 0.500 GHz, Option 220 or 225

Página 96

75 Dynamic Accuracy, 0.500 - 2 GHz, Option 220 or 225

Página 97

4 Corrected System Performance The specifications in this section apply for measurements made with the N5230A/C analyzer with the following condition

Página 99

77 Dynamic Accuracy, 2 - 12.5 GHz, Option 220 or 225

Página 101

79 Dynamic Accuracy, 12.5 - 20 GHz, Option 220 or 225

Página 103

81Options 420, 425, 520, 525 Dynamic Accuracy, 0.045 GHz, Option 420, 425, 520, or 525

Página 105

83 Dynamic Accuracy, 0.500 GHz, Option 420, 425, 520, or 525

Página 107 - Table 24. Typical Cycle Time

85 Dynamic Accuracy, 0.500 - 2 GHz, Option 420, 425, 520, or 525

Página 108

5 Table 1. System Dynamic Range1 (Continued) Description Specification (dB) at Test Port Typical (dB) at Test Port Options 025, 125 Option 22

Página 110 - Span = 100 MHz

87 Dynamic Accuracy, 2 - 8 GHz, Option 420, 425, 520, or 525

Página 112

89 Dynamic Accuracy, 8 - 12.5 GHz, Option 420, 425, 520, or 525

Página 114 - Output Power

91 Dynamic Accuracy, 12.5 - 20 GHz, Option 420, 425, 520, or 525

Página 116

93 Dynamic Accuracy, 20 - 31.25 GHz, Option 420, 425, 520, or 525

Página 118

95 Dynamic Accuracy, 31.25 - 40 GHz, Option 420, 425, 520, or 525

Comentários a estes Manuais

Sem comentários