used today—electrical lines, multimode, and single-mode
fiber. A built-in coupler reduces external hardware
requirements. All five modules have excellent jitter
performance to ensure accurate measurements. Each
clock recovery module is designed to synchronize to a
variety of common transmission rates.
Clock Recovery Loop Bandwidth
The Agilent clock recovery modules have two loop
bandwidth settings. Loop bandwidth is very important
in determining the accuracy of your waveform when
measuring jitter, as well as testing for compliance.
•Narrow loop bandwidth provides a clean system clock
for accurate jitter measurements
Wide loop bandwidth in some applications is specified
in the standards for compliance testing. It allows the
recovered clock to track the data and is useful for
extracting a signal that may have propagated through a
complex network and have large amounts of jitter. While
this obviously negates any ability to quantify the jitter,
it does allow other parameters of an eye to be measured.
Note: When using recovered clocks for triggering, jitter
measurement accuracy is suspect unless the scheme has
a very narrow loop bandwidth.
Improved Autoscaling
Autoscaling has been significantly improved to provide
quick horizontal and vertical scaling of both pulse and
eye-diagram (RZ and NRZ) waveforms.
Time Domain Reflectometer (TDR)
TDR measurements are focused on high-speed applica-
tions where it is necessary to optimize electrical system
components, such as microstrip lines, PC board traces,
SMA edge launchers and coaxial cables where imperfec-
tions cause signal distortion and reflections. Signal
integrity is a critical requirement in high-speed digital
signal transmission.
Gated Triggering
Trigger gating port allows easy external control of data
acquisition for circulating loop or burst-data experi-
ments. Use TTL-compatible signals to control when the
instrument does and does not acquire data.
Easier Calibrations
Calibrating your instrument has been simplified by
placing all the performance level indicators and calibra-
tion procedures in a single high-level location. This
provides greater confidence in the measurements made
and saves time in maintaining equipment.
Stimulus Response Testing
Using the Agilent N4906A Serial BERT
Error performance analysis represents an essential part
of digital transmission test. The Agilent 86100B and
N4906A SmartBERT have similar user interfaces and
together create a powerful test solution.
Transitioning from the Agilent 83480A and
86100A to the 86100B
The 86100B has been designed to be a virtual drop-in
replacement for the Agilent 86100A and Agilent 83480A
digital communications analyzers and Agilent 54750A
wide-bandwidth oscilloscope. All modules used in the
Agilent 83480A and 54750A can also be used in the
86100B. The remote programming command set for the
86100B has been designed for direct compatibility with
software written to control the 86100A, 83480A and
54750A.