Agilent Technologies Weather Radio 1680 Manual do Utilizador Página 1

Consulte online ou descarregue Manual do Utilizador para Componentes para chassis Agilent Technologies Weather Radio 1680. Agilent Technologies Weather Radio 1680 User's Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 0
Agilent Technologies 1680/90-Series
Logic Analyzer
Service Guide
Publication number 01680-97016
October 2005
For Safety information, Warranties, and Regulatory information, see the pages at the end
of the book.
© Copyright Agilent Technologies 2001, 2004-2005
All Rights Reserved.
Vista de página 0
1 2 3 4 5 6 ... 173 174

Resumo do Conteúdo

Página 1 - Logic Analyzer

Agilent Technologies 1680/90-Series Logic AnalyzerService GuidePublication number 01680-97016October 2005For Safety information, Warranties, and Regul

Página 2 - Features

10 Chapter 1: General InformationAccessories The following accessory is supplied with the Agilent 1680/90-series logic analyzers. The part number i

Página 3 - Service Strategy

100 Chapter 5: TroubleshootingTroubleshooting the Agilent 1690A,AD-seriesDevice ManagerUse Device Manager to see if the Agilent Logic Analyzer devic

Página 4 - In This Book

101Chapter 5: TroubleshootingTroubleshooting the Agilent 1690A,AD-seriesa Click on the Start button in the task bar, then select Shut Down.b In the

Página 5 - Contents

102 Chapter 5: TroubleshootingTroubleshooting the Agilent 1690A,AD-series6 Note problems with the power supply, then unplug the power supply from li

Página 6

103Chapter 5: TroubleshootingGeneral TroubleshootingGeneral TroubleshootingThis section includes troubleshooting procedures that can be done on eith

Página 7

104 Chapter 5: TroubleshootingGeneral Troubleshooting5 In the Analysis System Self Tests dialog, select the self test options:• Include interactive

Página 8

105Chapter 5: TroubleshootingGeneral TroubleshootingThe self tests can be run one at a time by clicking on the self-test of interest. The results of

Página 9

106 Chapter 5: TroubleshootingGeneral TroubleshootingAcquisition board status LEDsThe acquisition board has four LEDs located close to its IEEE 1394

Página 10 - Accessories

107Chapter 5: TroubleshootingGeneral TroubleshootingLED #1 (closest to the red LED) - the on-board processor is properly initialized and running, at

Página 11 - Characteristics

108 Chapter 5: TroubleshootingGeneral Troubleshooting2 Set up the pulse generator according to the following table.Pulse Generator Setup3 Using four

Página 12 - Auxiliary Power

109Chapter 5: TroubleshootingGeneral Troubleshootinge Click the Master button for the clock to be tested; then, select Both Edges.5 Configure the po

Página 13 - Dimensions

11Chapter 1: General InformationSpecificationsThe specifications are the performance standards against which the product is tested.CharacteristicsTh

Página 14 - Recommended Test Equipment

110 Chapter 5: TroubleshootingGeneral Troubleshootingsimilar to the figure below.7 Repeat steps 3 through 7 to test other logic analyzer cables.8 Di

Página 15 - Preparing for Use

111Chapter 5: TroubleshootingGeneral Troubleshootinganalyzer Trigger In BNC.c Using a BNC-banana cable, connect the voltmeter to the logic analyzer

Página 16 - To inspect the logic analyzer

112 Chapter 5: TroubleshootingGeneral TroubleshootingTo test the auxiliary powerThe +5 V auxiliary power is protected by a current overload protecti

Página 17 - To apply power

1136Replacing AssembliesThis chapter contains the instructions for removing and replacing the assemblies of the logic analyzer. Also in this chapter a

Página 18 - To test the logic analyzer

114 Chapter 6: Replacing Assemblies1680A,AD-series disassembly/assembly1680A,AD-series disassembly/assemblyPrepare the instrument for disassemblyDo

Página 19 - Testing Performance

115Chapter 6: Replacing Assemblies1680A,AD-series disassembly/assembly7 Reverse this procedure to install the chassis into the sleeve.When reassembl

Página 20 - Test Equipment

116 Chapter 6: Replacing Assemblies1680A,AD-series disassembly/assembly6 Slide the acquisition board out the rear panel of the logic analyzer.Steps

Página 21 - To make the test connectors

117Chapter 6: Replacing Assemblies1680A,AD-series disassembly/assemblyTo remove the power supply1 Do the procedure "To remove the chassis from

Página 22

118 Chapter 6: Replacing Assemblies1680A,AD-series disassembly/assembly6 Reverse this procedure to install the power supplyWhen installing a replace

Página 23 - Set up the test equipment

119Chapter 6: Replacing Assemblies1680A,AD-series disassembly/assemblyTo remove the CD-ROM drive assembly1 Do the procedure "To remove the chas

Página 24 - Chapter 8

12 Chapter 1: General InformationProbesMaximum Input Voltage + 40V Peak AC+DC, CAT 1Auxiliary PowerPower Through Cables 1/3 amp at 5 V maximum per c

Página 25

120 Chapter 6: Replacing Assemblies1680A,AD-series disassembly/assembly4 Using a Torx T-6 screwdriver, remove three screws that secure the CD-ROM dr

Página 26 - 5 Click Start

121Chapter 6: Replacing Assemblies1680A,AD-series disassembly/assembly3 Using a Torx T-8 screwdriver, remove two screws that secure the flexible dis

Página 27

122 Chapter 6: Replacing Assemblies1680A,AD-series disassembly/assemblyTo remove the PCI boardsThe following PCI boards are installed on the logic a

Página 28 - Set up the equipment

123Chapter 6: Replacing Assemblies1680A,AD-series disassembly/assemblyTo remove the motherboard1 Do the procedure "To remove the chassis from t

Página 29

124 Chapter 6: Replacing Assemblies1680A,AD-series disassembly/assembly6 Using a Torx T-10 screwdriver, remove the 6 screws that secure the motherbo

Página 30 - Test the ECL Threshold

125Chapter 6: Replacing Assemblies1680A,AD-series disassembly/assembly3 If the I/O panel requires replacement, then EMI gasket (01680-87102) must be

Página 31 - Test the 0 V User Threshold

126 Chapter 6: Replacing Assemblies1680A,AD-series disassembly/assemblyTo remove the front panel assembly1 Do the procedure "To remove the chas

Página 32 - Test the next pod

127Chapter 6: Replacing Assemblies1680A,AD-series disassembly/assembly6 Reverse this procedure to install the front panel assembly.After installing

Página 33

128 Chapter 6: Replacing Assemblies1680A,AD-series disassembly/assemblyTo disassemble the front panel assemblyRemove the front panel circuit board.1

Página 34

129Chapter 6: Replacing Assemblies1680A,AD-series disassembly/assemblyReverse this procedure to assemble the front panel assembly.If the front panel

Página 35

13Chapter 1: General InformationDimensions1680A,AD-Series1690A,AD-Series

Página 36 - “from” field

130 Chapter 6: Replacing Assemblies1680A,AD-series disassembly/assembly5 Reverse this procedure to install the distribution board.To remove the inve

Página 37

131Chapter 6: Replacing Assemblies1680A,AD-series disassembly/assembly5 Reverse this procedure to install the inverter board.To remove the fans1 Do

Página 38

132 Chapter 6: Replacing Assemblies1680A,AD-series disassembly/assemblyTo remove the cable trayDo the following steps only if the cable tray require

Página 39

133Chapter 6: Replacing Assemblies1690A,AD-series disassembly/assembly1690A,AD-series disassembly/assemblyPrepare the instrument for disassemblyDo t

Página 40 - Verify the test signal

134 Chapter 6: Replacing Assemblies1690A,AD-series disassembly/assembly6 Reverse this procedure to install the chassis into the sleeve.When reassemb

Página 41

135Chapter 6: Replacing Assemblies1690A,AD-series disassembly/assembly4 Remove the fascia away from the front panel.If the fascia requires replaceme

Página 42

136 Chapter 6: Replacing Assemblies1690A,AD-series disassembly/assemblyTo remove the acquisition board1 Do the following procedures:To remove the ch

Página 43

137Chapter 6: Replacing Assemblies1690A,AD-series disassembly/assemblyTo remove the deck1 Using a Torx T-10 screwdriver, remove four screws that sec

Página 44

138 Chapter 6: Replacing Assemblies1690A,AD-series disassembly/assembly5 Lift the power supply out of the chassis.6 Reverse this procedure to instal

Página 45

139Chapter 6: Replacing Assemblies1690A,AD-series disassembly/assembly4 Slide the distribution board up approx 1 cm, then lift the board away from t

Página 46

14 Chapter 1: General InformationRecommended Test EquipmentEquipment RequiredEquipment Critical Specifications Recommended Model/PartUse*Pulse Gener

Página 47

140 Chapter 6: Replacing Assemblies1690A,AD-series disassembly/assembly6 Reverse this procedure to install the fans.To remove the line filter1 Do th

Página 48

141Chapter 6: Replacing Assemblies1690A,AD-series disassembly/assemblyTo remove the front panel and front frame1 Do the following procedures:To remo

Página 49

142 Chapter 6: Replacing Assemblies1690A,AD-series disassembly/assembly

Página 50

1437Replaceable PartsThis chapter contains information for identifying and ordering replaceable parts for your logic analyzer.

Página 51

144 Chapter 7: Replaceable PartsReplaceable Parts OrderingParts listedTo order a part on the list of replaceable parts, quote the Agilent Technologi

Página 52

145Chapter 7: Replaceable PartsExchange AssembliesSome assemblies are part of an exchange program with Agilent Technologies.The exchange program all

Página 53

146 Chapter 7: Replaceable PartsExploded ViewExploded view of the Agilent 1680A,AD-series logic analyzer

Página 54

147Chapter 7: Replaceable PartsAgilent 1680A,AD-Series Replaceable PartsReplaceable PartsRef. Des. Agilent Part Number QTY Description Exchange As

Página 55

148 Chapter 7: Replaceable PartsE3 5090-4833 6 Grabber Kit Assembly (1681A, AD)E3 5090-4833 4 Grabber Kit Assembly (1682A, AD)E3 5090-4833 2 Grabber

Página 56

149Chapter 7: Replaceable PartsH11 0515-0430 6 M3.0 x 5.0; 6 mm T10; motherboard to chassisMP1 01660-09101 4 Ground Spring (1680A, AD)MP1 01660-0910

Página 57

152Preparing for UseThis chapter gives you instructions for preparing the logic analyzer for use.

Página 58

150 Chapter 7: Replaceable PartsMP25 01681-94302 1 ID Label (1681AD)MP25 01682-94301 1 ID Label (1682A)MP25 01682-94302 1 ID Label (1682AD)MP25 0168

Página 59

151Chapter 7: Replaceable PartsW12 16600-61602 1 Power Sense Cable (power supply to distribution board)W13 16700-61604 1 Power Supply Cable (16-pin

Página 60

152 Chapter 7: Replaceable PartsMP41 1400-0611 1 Cable Clamp, 1 in x 1 in adhesive backed (LCD to LCD display)MP42 54801-47401 3 Knob 12 MM Flint Gr

Página 61

153Chapter 7: Replaceable PartsExploded ViewExploded view of the Agilent 1690A,AD-series logic analyzer

Página 62

154 Chapter 7: Replaceable PartsAgilent 1690A,AD-Series Replaceable PartsReplaceable PartsRef. Des. Agilent Part Number QTY Description Exchange A

Página 63

155Chapter 7: Replaceable PartsH1 0515-0372 31 M3.0 x 0.50; 8 mm T10 PH (distribution board to chassis, deck to chassis, probe shroud to acquisition

Página 64

156 Chapter 7: Replaceable Parts01690-41901 On/Off Keypad01690-44101 Fascia01690-61602 On/Off Cable0515-1934 M2.5 x 0.45; 6 mm T8 PH (power switch i

Página 65

157Chapter 7: Replaceable PartsPower Cables and Plug ConfigurationsThis instrument is equipped with a three-wire power cable. The type of power cab

Página 66

158 Chapter 7: Replaceable PartsOpt 918100V8120-4754 90° 90/230 JapanOpt 9218120-6979 90° ChileOpt 9228120-8377 90° People’s Republic of ChinaOpt 92

Página 67

1598Theory of OperationThis chapter tells the theory of operation for the logic analyzer and describes the self-tests.

Página 68

16 Chapter 2: Preparing for UsePower RequirementsThe logic analyzer requires a power source of either 115 Vac or 230 Vac, –22 % to +10 %, single pha

Página 69

160 Chapter 8: Theory of OperationThe information in this chapter will help you understand how the logic analyzer operates and what the self-tests a

Página 70

161Chapter 8: Theory of OperationAgilent 1680A,AD-series Logic Analyzer TheoryAgilent 1680A,AD-series Logic Analyzer TheoryPC Motherboard. The Agile

Página 71

162 Chapter 8: Theory of OperationAgilent 1680A,AD-series Logic Analyzer TheoryPower SupplyA low voltage power supply provides all the DC voltages n

Página 72

163Chapter 8: Theory of OperationAgilent 1680A,AD-series Logic Analyzer TheoryThe probe tip networks are comprised of a series of resistors (250 Ohm

Página 73

164 Chapter 8: Theory of OperationAgilent 1680A,AD-series Logic Analyzer Theoryresent via DMA transactions to an IEEE 1394 Link Layer chip. The Link

Página 74

165Chapter 8: Theory of OperationAgilent 1680A,AD-series Logic Analyzer TheoryPower Distribution BoardThe power distribution board connects directly

Página 75 - Calibrating and Adjusting

166 Chapter 8: Theory of OperationAgilent 1690A,AD-series Logic Analyzer TheoryAgilent 1690A,AD-series Logic Analyzer TheoryAcquisition BoardThe Agi

Página 76 - Logic analyzer calibration

167Chapter 8: Theory of OperationSelf-Tests DescriptionsSelf-Tests DescriptionsThe self-tests identify the correct operation of major functional are

Página 77 - Troubleshooting

168 Chapter 8: Theory of OperationSelf-Tests DescriptionsAcquisition Board Self TestsThe acquisition board self tests are available in the Agilent L

Página 78 - To install the fan guard

169Chapter 8: Theory of OperationSelf-Tests DescriptionsTrigger Arm Test. The Trigger Arm Test verifies that the local arm signal can be received by

Página 79 - To use the flowcharts

17Chapter 2: Preparing for Use3 Inspect the product for physical damage.Check the logic analyzer and the supplied accessories for obvious physical o

Página 80

170 Chapter 8: Theory of OperationSelf-Tests Descriptionsverified that each register has been initialized. Test patterns are then written to ensure

Página 81

171Chapter 8: Theory of OperationSelf-Tests Descriptionsconfigured to take a simple measurement. Test data is then created at the comparators and an

Página 82

172 Chapter 8: Theory of OperationSelf-Tests Descriptions

Página 83

Notices© Agilent Technologies, Inc. 2001, 2004-2005No part of this manual may be reproduced in any form or by any means (including elec-tronic storage

Página 85

18 Chapter 2: Preparing for UseTo start the user interfaceStart the Agilent Logic Analyzer application from the Start menu or using a shortcut. On t

Página 86

193Testing PerformanceThis chapter tells you how to test the performance of the logic analyzer against the specifications listed in chapter 1.

Página 87 - To check the power-up tests

2 The Agilent 1680/90-Series Logic Analyzer–At a GlanceFeaturesSome of the main features of the Agilent 1680A,AD-Series Logic Analyzers are as follo

Página 88

20 Chapter 3: Testing PerformanceThe Logic Analyzer InterfaceTo select a field on the logic analyzer screen, use the arrow keys to highlight the fie

Página 89 - 01680f01.cdr

21Chapter 3: Testing PerformanceTo make the test connectorsTo make the test connectorsThe test connectors connect the logic analyzer to the test equ

Página 90 - To test disk drive voltages

22 Chapter 3: Testing PerformanceTo make the test connectorsf On two of the test connectors, solder a 20:1 probe. The probe ground goes to the same

Página 91

23Chapter 3: Testing PerformanceTo set up the test equipment and the logic analyzerTo set up the test equipment and the logic analyzerBefore testing

Página 92 - To verify the CD-ROM

24 Chapter 3: Testing PerformanceTo set up the test equipment and the logic analyzerb Configure the oscilloscope according to the following table.Os

Página 93

25Chapter 3: Testing PerformanceTo set up the test equipment and the logic analyzerSet up the 1690A,AD-series logic analyzerPower-up self tests are

Página 94

26 Chapter 3: Testing PerformanceTo set up the test equipment and the logic analyzer2 In the Analysis System Self Tests dialog, select the self test

Página 95

27Chapter 3: Testing PerformanceTo set up the test equipment and the logic analyzerTo stop running test, click Stop.To reset the self-test options,

Página 96

28 Chapter 3: Testing PerformanceTo test the threshold accuracyTo test the threshold accuracyTesting the threshold accuracy verifies the performance

Página 97

29Chapter 3: Testing PerformanceTo test the threshold accuracyConnect and configure the logic analyzer1 Using the 17-by-2 test connector, BNC cable,

Página 98

3Service StrategyThe service strategy for this instrument is the replacement of defective assemblies. This service guide contains information for f

Página 99 - To verify connectivity

30 Chapter 3: Testing PerformanceTo test the threshold accuracyTest the ECL Threshold1 Set up the logic analyzer:a In the Analyzer Setup dialog, cli

Página 100 - 2 Shut down the instrument

31Chapter 3: Testing PerformanceTo test the threshold accuracyTest the 0 V User Threshold1 Set up the logic analyzer:a On the logic analyzer, click

Página 101

32 Chapter 3: Testing PerformanceTo test the threshold accuracyTest the next pod1 Using the 17-by-2 test connector and probe tip assembly, connect t

Página 102 - Chapter 5: Troubleshooting

33Chapter 3: Testing PerformanceTo set up the logic analyzer for the state mode testsTo set up the logic analyzer for the state mode tests1 Set up t

Página 103 - General Troubleshooting

34 Chapter 3: Testing PerformanceTo set up the logic analyzer for the state mode tests3 Configure the trigger according to your logic analyzer:a In

Página 104 - 8 Click Start

35Chapter 3: Testing PerformanceTo set up the logic analyzer for the state mode testsselect the M1 marker.c In the Position box, select Value.d Clic

Página 105

36 Chapter 3: Testing PerformanceTo set up the logic analyzer for the state mode testsh Repeat steps b through f to configure marker M2 using the fo

Página 106 - Acquisition board status LEDs

37Chapter 3: Testing PerformanceTo test the single-clock, single-edge, state acquisitionTo test the single-clock, single-edge, state acquisitionTest

Página 107

38 Chapter 3: Testing PerformanceTo test the single-clock, single-edge, state acquisition2 Using SMA cables, connect the oscilloscope to the pulse g

Página 108

39Chapter 3: Testing PerformanceTo test the single-clock, single-edge, state acquisitionConnect the 1682/83/92/93A,AD Logic Analyzer to the Pulse Ge

Página 109

4 In This BookThis book is the service guide for the Agilent 1680/90-Series Logic Analyzers and is divided into eight chapters.Chapter 1 contains in

Página 110

40 Chapter 3: Testing PerformanceTo test the single-clock, single-edge, state acquisitionVerify the test signal1 Check the clock period. Using the

Página 111

41Chapter 3: Testing PerformanceTo test the single-clock, single-edge, state acquisitionc If the pulse width is outside the limits, adjust the pulse

Página 112 - To test the auxiliary power

42 Chapter 3: Testing PerformanceTo test the single-clock, single-edge, state acquisitionc On the oscilloscope, select [Shift] ∆ Time, then select [

Página 113 - Replacing Assemblies

43Chapter 3: Testing PerformanceTo test the single-clock, single-edge, state acquisitiond Click OK to close the Sample Positions dialog.4 Select the

Página 114

44 Chapter 3: Testing PerformanceTo test the single-clock, single-edge, state acquisitionc Click the Master buttons for the remaining clocks and sel

Página 115

45Chapter 3: Testing PerformanceTo test the single-clock, single-edge, state acquisitionthen select [Enter] to display the setup time (∆ Time(1)-(2)

Página 116

46 Chapter 3: Testing PerformanceTo test the single-clock, single-edge, state acquisitionc Click the Master buttons for the remaining clocks and sel

Página 117 - To remove the power supply

47Chapter 3: Testing PerformanceTo test the single-clock, single-edge, state acquisitionTest the next channels (1680/81A,AD and 1690/91A,AD)Connect

Página 118 - To remove the hard disk drive

48 Chapter 3: Testing PerformanceTo test the multiple-clock state acquisitionTo test the multiple-clock state acquisitionTesting the multiple-clock,

Página 119

49Chapter 3: Testing PerformanceTo test the multiple-clock state acquisitionConnect and configure the logic analyzer1 Using the 6-by-2 test connecto

Página 120

Contents 5The Agilent 1680/90-Series Logic Analyzer–At a GlanceFeatures 2Service Strategy 3In This Book1 General InformationAccessories 10Specificati

Página 121 - Apply the tape as shown

50 Chapter 3: Testing PerformanceTo test the multiple-clock state acquisitionConnect the 1682/83/92/93A,AD Logic Analyzer to the Pulse Generator 3 A

Página 122 - To remove the PCI boards

51Chapter 3: Testing PerformanceTo test the multiple-clock state acquisitionVerify the test signal1 Check the clock period. Using the oscilloscope,

Página 123 - To remove the motherboard

52 Chapter 3: Testing PerformanceTo test the multiple-clock state acquisitionb On the oscilloscope, select [Shift] + width: channel 1, then select [

Página 124

53Chapter 3: Testing PerformanceTo test the multiple-clock state acquisitionb In the oscilloscope timebase menu, select Position. Using the oscillos

Página 125

54 Chapter 3: Testing PerformanceTo test the multiple-clock state acquisitiond Connect all clock channels to the pulse generator channel 1 output.e

Página 126

55Chapter 3: Testing PerformanceTo test the multiple-clock state acquisition6 Enable the pulse generator channel 1 COMP (with the LED on).7 Using th

Página 127

56 Chapter 3: Testing PerformanceTo test the multiple-clock state acquisitionhave been configured with Falling Edge.d Click OK to close the Analyzer

Página 128

57Chapter 3: Testing PerformanceTo test the single-clock, multiple-edge, state acquisitionTo test the single-clock, multiple-edge, state acquisition

Página 129

58 Chapter 3: Testing PerformanceTo test the single-clock, multiple-edge, state acquisitionConnect and configure the logic analyzer1 Using the 6-by-

Página 130 - To remove the inverter board

59Chapter 3: Testing PerformanceTo test the single-clock, multiple-edge, state acquisitionConnect the 1682/83/92/93A,AD Logic Analyzer to the Pulse

Página 131 - To remove the fans

6 ContentsTo test the threshold accuracy 28Set up the equipment 28Connect and configure the logic analyzer 29Test the ECL Threshold 30Test the 0 V Us

Página 132 - To remove the cable tray

60 Chapter 3: Testing PerformanceTo test the single-clock, multiple-edge, state acquisitionVerify the test signal1 Check the clock period. Using th

Página 133

61Chapter 3: Testing PerformanceTo test the single-clock, multiple-edge, state acquisition2 Check the data pulse width. Using the oscilloscope, ver

Página 134 - To remove the fascia

62 Chapter 3: Testing PerformanceTo test the single-clock, multiple-edge, state acquisition1 Using the Delay mode of the pulse generator channel 2,

Página 135

63Chapter 3: Testing PerformanceTo test the single-clock, multiple-edge, state acquisitiond Click OK to close the Sample Positions dialog.3 Select t

Página 136

64 Chapter 3: Testing PerformanceTo test the single-clock, multiple-edge, state acquisitionto turn off the other clocks.d Connect the clock to be te

Página 137 - To remove the deck

65Chapter 3: Testing PerformanceTo test the single-clock, multiple-edge, state acquisitionTest the next channels (1680/81A,AD and 1690/91A,AD)Connec

Página 138

66 Chapter 3: Testing PerformanceTo test the time interval accuracyTo test the time interval accuracy Testing the time interval accuracy does not ch

Página 139

67Chapter 3: Testing PerformanceTo test the time interval accuracy3 Set up the function generator according to the following table.Function Generato

Página 140 - To remove the line filter

68 Chapter 3: Testing PerformanceTo test the time interval accuracyd Select an Acquisition Depth of 256K.5 Configure the logic analyzer channels:a C

Página 141

69Chapter 3: Testing PerformanceTo test the time interval accuracyb In the pop-up menu, select Rising Edge.Acquire and verify the test data1 Click t

Página 142

Contents 75 TroubleshootingTo install the fan guard 78To use the flowcharts 79Troubleshooting the Agilent 1680A,AD-series 80To check the power-up tes

Página 143 - Replaceable Parts

70 Chapter 3: Testing PerformanceTo test the time interval accuracyf Click OK to close the Value dialog.3 Set up the M2 marker for time interval mea

Página 144 - Replaceable Parts Ordering

71Chapter 3: Testing PerformancePerformance Test RecordPerformance Test Record Agilent 1680/90-Series Logic Analyzer_______Serial No.______________

Página 145 - Replaceable Parts List

72 Chapter 3: Testing PerformancePerformance Test RecordPerformance Test Record (continued)Test Settings ResultsSingle-Clock, Single-Edge Acquisitio

Página 146 - Exploded View

73Chapter 3: Testing PerformancePerformance Test RecordPerformance Test Record (continued)Test Settings ResultsSingle-Clock, Multiple-Edge Acquisiti

Página 147 - Replacement Parts

74 Chapter 3: Testing PerformancePerformance Test Record

Página 148

754Calibrating and AdjustingThis chapter gives you instructions for calibrating and adjusting the logic analyzer.

Página 149

76 Chapter 4: Calibrating and AdjustingLogic analyzer calibrationThe logic analyzer circuitry of the Agilent 1680/90-series logic analyzers does not

Página 150

775TroubleshootingThis chapter helps you troubleshoot the logic analyzer to find defective assemblies.

Página 151 - Front Panel Assembly

78 Chapter 5: TroubleshootingThe troubleshooting consists of flowcharts, self-test instructions, and tests. This information is not intended for co

Página 152

79Chapter 5: Troubleshootingc Install the optional screws as shown.3 After the required power-on troubleshooting and repair is complete, reverse the

Página 153

8 Contents1690A,AD-series disassembly/assembly 133Prepare the instrument for disassembly 133To remove the chassis from the sleeve 133To remove the fa

Página 154

80 Chapter 5: TroubleshootingTroubleshooting the Agilent 1680A,AD-seriesTroubleshooting the Agilent 1680A,AD-seriesApply power. Observethe instrume

Página 155

81Chapter 5: TroubleshootingTroubleshooting the Agilent 1680A,AD-seriesAre the powersupply fansrunning?Ensure the power cordis properly connected.Is

Página 156

82 Chapter 5: TroubleshootingTroubleshooting the Agilent 1680A,AD-seriesAre the fanvoltages OK?Verify the fan voltage.Perform "To test thefan v

Página 157 - Chapter 7: Replaceable Parts

83Chapter 5: TroubleshootingTroubleshooting the Agilent 1680A,AD-seriesConnect an external800x600 PC monito tothe instrument.Does the externalmonito

Página 158

84 Chapter 5: TroubleshootingTroubleshooting the Agilent 1680A,AD-series* Microsoft Windows XP Technical Resourceswill help identify the cause of sp

Página 159 - Theory of Operation

85Chapter 5: TroubleshootingTroubleshooting the Agilent 1680A,AD-seriesUninstall, then reinstallthe Agilent LogicAnalyzer application.Does theapplic

Página 160 - Block-Level Theory

86 Chapter 5: TroubleshootingTroubleshooting the Agilent 1680A,AD-seriesPossible problem withlogic analyzer cables. Dothe cable test in Chapter5 on

Página 161

87Chapter 5: TroubleshootingTroubleshooting the Agilent 1680A,AD-seriesTo check the power-up testsThe power-up self tests on the 1680A,AD-series log

Página 162 - Acquisition Board

88 Chapter 5: TroubleshootingTroubleshooting the Agilent 1680A,AD-series3 Remove the power supply from the instrument. Refer to “To remove the power

Página 163

89Chapter 5: TroubleshootingTroubleshooting the Agilent 1680A,AD-seriesTo test the LCD display signalsBefore attempting to do this procedure, ensure

Página 164

91General InformationThis chapter lists the accessories, the specifications and characteristics, and the recommended test equipment.

Página 165 - Front Panel Board

90 Chapter 5: TroubleshootingTroubleshooting the Agilent 1680A,AD-series4 Using an oscilloscope, probe pins 39 and 40 of J111 for +3.3VdcIf +3.3Vdc

Página 166

91Chapter 5: TroubleshootingTroubleshooting the Agilent 1680A,AD-seriesb As the instrument is booting, probe for digital signals on the hard disk dr

Página 167 - Self-Tests Descriptions

92 Chapter 5: TroubleshootingTroubleshooting the Agilent 1680A,AD-seriese While the instrument is attempting to save the file to flexible disk, prob

Página 168 - Acquisition Board Self Tests

93Chapter 5: TroubleshootingTroubleshooting the Agilent 1680A,AD-seriesTo recover the operating systemTo reinstall the operating systemReinstalling

Página 169 - Logic Analyzer Self-Tests

94 Chapter 5: TroubleshootingTroubleshooting the Agilent 1680A,AD-seriesthe application software.Problems with the Operating SystemOperating system

Página 170

95Chapter 5: TroubleshootingTroubleshooting the Agilent 1690A,AD-seriesTroubleshooting the Agilent 1690A,AD-seriesApply power.Launch theAgilent Logi

Página 171

96 Chapter 5: TroubleshootingTroubleshooting the Agilent 1690A,AD-seriesReconnect thepower cord.Are the instrumentfans running?Suspect the power sup

Página 172

97Chapter 5: TroubleshootingTroubleshooting the Agilent 1690A,AD-seriesPossible problem withhost operating system.Consult host PCdocumentation.Is th

Página 173 - Acknowledgements

98 Chapter 5: TroubleshootingTroubleshooting the Agilent 1690A,AD-seriesPossible problem withlogic analyzer cables. Dothe cable test in Chapter5 on

Página 174

99Chapter 5: TroubleshootingTroubleshooting the Agilent 1690A,AD-seriesTo verify connectivityUsing Windows Device Manager and Task Manager, you can

Comentários a estes Manuais

Sem comentários