Agilent 75000 SERIES B
E1300B/E1301B Mainframe
E1306A Command Module
Memory Module
Installation Note
Copyright© Agilent Technologies, Inc., 1995, 2006
*E1300-90027*
E1300-90027
E0206
Manual Part Number: E1300-90027
Microfiche Part Number: E1300-99027
Printed: February 2006 Edition 2
Printed in U.S.A. E0206
Vista de página 0
1 2 3 4 5 6 ... 15 16

Resumo do Conteúdo

Página 1 - *E1300-90027*

Agilent 75000 SERIES BE1300B/E1301B MainframeE1306A Command ModuleMemory ModuleInstallation NoteCopyright© Agilent Technologies, Inc., 1995, 2006*E130

Página 2

Step 9: Remove the controller module’s ribbon cable connector(s) (the E1300 has one ribboncable, the E1301 has two cables). Push the controller modu

Página 3

For example, in the figure above, the four Most Significant Bit (MSB) switches are shown in the "1" position,the next bit is shown in the &

Página 4 - Safety Symbols

Step 12: Reassemble the mainframe.Step 11: Install the memory module(s) and fasten with the Torx® screws provided.1-8 Installing Memory into an Agi

Página 5 - E1300B/E1301B Mainframe

Chapter 2Installing Memory into anAgilent E1306A Command ModuleDescriptionYou can install one or two 1MByte memory modules into an Agilent E1306A Co

Página 6

Installation ProcedureStep 1: If the Agilent E1306A Command Module is installed in a mainframe, disconnectpower to the mainframe and remove the Comma

Página 7 - Remove with T10 Torx Key

Step 3: Set the memory module address switch(es) according to Table 2-1.For example, in the figure above, the four Most Significant Bit (MSB) switch

Página 8 - T10 Torx Screw

Step 4: Install the memory module and fasten with two Torx® screws.Step 5: (Optional) Install second memory module and fasten with four Torx® scre

Página 10

CertificationAgilent Technologies certifies that this product met its published specifications at the time of shipment from the factory. Agilent Tech

Página 11 - Address Switch

Frame or chassis ground terminal—typi-cally connects to the equipment’s metalframe.Alternating current (AC).Direct current (DC). Indicates hazardous v

Página 12

Chapter 1Installing Memory into an AgilentE1300B/E1301B MainframeDescriptionYou can install one or two memory modules onto the controller circuit boa

Página 13 - Agilent E1306A Command Module

Installation ProcedureStep 1: Disconnect the mainframe’s power.Remove with Phillips orPozi-drive ScrewdriverStep 2: Remove the mainframe’s side handle

Página 14 - Installation Procedure

Step 4: Slide the top cover toward the rear, lift and remove the cover.Remove with T10 Torx KeyStep 3: Remove the Torx® screws on the rear of the ma

Página 15

Step 6: If you have an internal Agilent E1326 5 1/2 Digit Multimeter, disconnect the BNCcable, and remove the three Torx® screws. T10 Torx ScrewSpac

Página 16

Step 8: Remove the three T10 Torx® screws securing the controller board.Step 7: Remove the multimeter.Installing Memory into an Agilent E1300B/E1301