Downloading and Using Files
User File Data Downloads
Chapter 4172
For this protocol configuration, the signal generator’s firmware loads PRAM with the bits
defined in the following table.
Event 1 output is set to 0 or 1 depending on the sync out selection, which enables the Event 1
output at either the beginning of the frame, beginning of a specific timeslot, or at all timeslots.
Frame Timeslot PRAM
Address
Data Bits Burst Bits Pattern
Reset Bit
1 0 0 -155 0/1 (don’t care) 0 (off) 0 (off)
1 1 (on) 156 - 311 set by GSM standard (42 bits)
& first 114 bits of user file
1 (on) 0
1 2 312 - 467 0/1 (don’t care) 0 0
1 3 468 - 624 0/1 (don’t care) 0 0
1 4 625 - 780 0/1 (don’t care) 0 0
1 5 781 - 936 0/1 (don’t care) 0 0
1 6 937 - 1092 0/1 (don’t care) 0 0
1 7 1093 - 1249 0/1 (don’t care) 0 0
2 0 1250 - 1405 0/1 (don’t care) 0 0
2 1 (on) 1406 - 1561 set by GSM standard (42 bits)
& remaining bits of user file
1 (on) 0
2 2 through
6
1562 - 2342 0/1 (don’t care) 0 0 (off)
2 7 2343 - 2499 0/1 (don’t care) 0 0
(1 in
address
2499 only)