Agilent N9360A Mobile Station Tester Technical Overview
10 cdma2000 is a registered certification mark of the Telecommunications Industry Association. Us
2 Go/No go multi-format cellular device tester for mobile station service and repair with built-in PC When your cellular phone repair, manufactur
3 Technical Specifications Specifications describe the test set’s warranted performance and are valid over the entire operation and environmental r
4 W-CDMA/HSDPA Modulated Power Measurement Range: 0 to +36 dBm; (-30 to +36 dBm)1 Resolution: 0.1 dB Accuracy: ≤ ±0.7 dB (25 ±5 °C), typical = ±0.4
5 cdma2000/1xEV-DO Modulated Power Measurement Range: −53 to +36 dBm; (−60 to +36 dBm)1 Resolution: 0.1 dB Accuracy: ≤ ±1.0 dB (25 ±5 °C), ≤ ±1.5 d
6 RF Signal Generator for W-CDMA/HSDPA Modulation: W-CDMA: QPSK, Off: CW, FM1 FM Modulation1: Rate = 50kHz, Deviation = 500kHz Modulation accuracy:
7 GSM/GPRS/EGPRS Test Coverage GSM Transmitter Tests • Phase and frequency error • Tx output power (normal burst) • Monotonic power sequence •
8 GSM/GPRS/EGPRS/W-CDMA Test Features GSM • Location update • MS call • BS call • MS release • BS release • TCH loop • Voice loopback • Eme
9 1xEV-DO Test Features Protocol Test • UATI assignment • Session opened • BS call • RF test • Softer handoff • Connection close • Session c