Agilent Technologies Agilent E5250A Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Comutadores de rede Agilent Technologies Agilent E5250A. Agilent E5250A Low Leakage Switch Mainframe Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 4
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0





Agilent E5250A Low Leakage
Switch Mainframe functions:
Switches DC current, DC voltage,
capacitance and pulse with DC
instruments and LCR meters
Controls switching through built-
in GPIB
Performs self test using Option
301 relay function test adapter

Option 001 10 x 12 matrix switch:
From 10 x 12 to 10 x 48 matrix
per frame. (Option 001 x 1 to 4)
Option 501 24-channel (8 x 3)
multiplexer:
From 24 to 96 channels per frame
(Option 501 x 1 to 4)
Required cables and connector
plates are available.

The E5250A includes a program
disk (3.5-inch LIF format) that
contains two utility and three
sample programs.
Utility programs:
Virtual front panel, self test
(IBASIC)
Sample programs and routines:
C compensation using Agilent
4284A application samples for
this matrix switch and multi-
plexer. (HP BASIC) VFP setup
data upload (HP BASIC)

The Supplemental Information
and Typical Data entries in the
following specifications are not
warranted but they provide useful
information about the functions and
performance of the instruments.
Specifications, typical data, and
supplemental information are
defined at 23º C ± 5º < 60% relative
humidity (RH).
Vista de página 0
1 2 3 4

Resumo do Conteúdo

Página 1 - 

Agilent E5250A Low LeakageSwitch Mainframe functions:• Switches DC

Página 2 - 

Temperature RangeOperating: 5º C to 40º CStorage: -40º C to 70º CHumidity RangeOperating: 5% to 80% (no condensation)Storage: 5

Página 3 - 

Offset current: < 0.1 pA1(Low Leakage I-V Port)< 1000 pA1(General I-V Port)Channel Crosstalk Capacitance: < 0.3 pF/chOffset volt

Página 4 - % 

% 16494A Triaxial Cable16494B Kelvin Triaxial Cable16494C Kelvin Triaxial Cable for 414216494D 8 ch Shielded Coaxial Cable1649

Comentários a estes Manuais

Sem comentários