Agilent 34970AData Acquisition/Switch Unit Product Overview Agilent performance at a fraction of the cost of other standalone data acquisition syste
10Low-cost, high-quality switching for automated testIf you don’t need the built-in measurement capability of the 34970A, save money by ordering it wi
11Customize your Agilent 34970A with-plug-in modulesA complete selection of plug-in modules gives you high-quality measurement, switching, and control
12Agilent QualityWe know you can’t afford instrument downtime due to hardware failures and unscheduled mainte-nance. That’s why our engineers designed
13Spec Interpretation GuideThe following pages list the technical specifications for the Agilent-34970A Data Acquisition/Switch Unit and its modules.
[1] Specifications are for 1 hr warm-up and 61/2 digits, Slow ac filter[2] Relative to calibration standards[3] 20% over range on all ranges except 30
15Measurement Characteristics[8]DC VoltageMeasurement Method Continuously Integrating Multi-slope III A-D ConverterA-D Linearity 0.0002% of readin
16[1] Storage at temperatures above 40°C will decrease battery life[2] Software provided on CD-ROM and includes utility to create floppy disks for ins
17Modules SpecificationsThe Agilent-34970A accuracy specifications already include the switching offset and reference junction errors shown below. Th
18Multiplexer Selection-GuideChoose between the broad functionality of the 34901A, the-high speed scanning of the 34902A, or the single-ended density
1934902A16-Channel High-Speed Multiplexer• 250 ch/s scanning• Two- and four-wire scanning • Built-in thermocouple reference junctionThe Agilent 3490
4 6 7 8 9 10 11 11 12 13 14 16 16 17 18 20 20 21 22 23 24Table of ContentsFeaturesUsing the 34970A for data logging applicationsData Logging Feature
2034903A20-Channel Actuator/General Purpose Switch• SPDT (Form C) latching relays• 300 V, 1A actuation and controlThis general-purpose switch module
0 dB-1 dB-2 dB-3 dB-4 dB10 MHz 100 MHz 1 GHz 3 GHz1.801.601.401.201.0010 MHz 100 MHz 1 GHz 3 GHz-20 dB-40 dB-60 dB-80 dB-100 dB10 MHz 100 MHz 1 GHz 3
34907AMultifunction Module• 16 bits of digital input and output• 100 kHz totalizer input• Two ±12V analog outputsThe Agilent 34907A allows great fle
23Rack Mounting and DimensionsTo rack mount a single instrument, order adapter kit 5063-9240 (Option 1CM).To rack mount two instruments side-by-side,
Agilent Technologies’ Test and Measurement Support, Services, and AssistanceAgilent Technologies aims to maximize the value you receive, while minimiz
3Price and performance beyond compareGo ahead and compare the Agilent Technologies 34970A Data Acquisition/Switch Unit with other data acquisition sys
43-slot mainframe offers up to 96 matrix crosspoints or 120 single-ended channelsAgilent BenchLink Data Logger 3 software included; drivers available
5The Agilent 34970A offers unequaled-versatility for your data acquisition applicationsIn the past, you had to make a choice. On the one hand, you cou
6An easy-to-use data logger for-monitoring and characterization applicationsData loggers are used to monitor multiple signals (temperature, voltage, e
And the 34970A measures and converts 11 different input signals:• temperature with thermocouples, RTDs, and thermistors • dc and ac volts• 2- and 4-
A powerful, flexible data acquisition system for automated-testThe 34970A gives you the resolution, accuracy, repeatability, and speed you’ve come to
9Software driversYour months of test system software development time need not go to waste. Software drivers that support Agilent VEE and National Ins
Comentários a estes Manuais