Agilent Technologies N9320A Guia do Utilizador Página 81

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 178
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 80
Key Reference 4
N9320A Spectrum Analyzer 73
Auto Tune
Activates the autotune function to view the signal, This
hardkey functions as following description:
1 Run Peak Search in full span
2 Run Mkr -> CF
3 Select the appropriate reference level according to the
amplitude of searching signal.
4 Set span to 1 MHz and all auto couple to view the signal.
For more information about Peak Search, Mkr CF and
Mkr Ref Lel softkeys, please refer to “Peak Search” on
page 103, and “Marker- >” on page 97.
NOTE
The Auto Tune functions in the frequency range of 5 MHz to 3 GHz.
The minimum detectable amplitude is –65 dBm.