53210A
350 MHz, 10-digit/s RF counter
53220A
350 MHz, 12 digit/s, 100 ps universal
frequency counter / timer
53230A
350 MHz, 12-digit/s, 20 ps universal
frequency counter / timer
Inputs
Standard channels
(Option 201 adds parallel rear panel inputs)
Ch 1: DC – 350 MHz Ch 1 and Ch 2: DC – 350 MHz
Impedance, coupling Selectable 1 M Ω ± 1.5% or 50 Ω ± 1.5% || <25 pF; Selectable DC or AC coupling
Amplitude input range ±5 V (±50 V) full scale ranges; ±500 V range available with 10:1 probe on counter input
Input event threshold level ±5 V (±50 V) in 2.5 mV (25 mV) steps
Sensitivity DC–100 MHz: 20 mVpk; > 100 MHz: 40 mVpk
Optional microwave channel – front type N
(Option 203 moves the input connector
to a rear panel SMA(f))
Opt Ch 2 Opt Ch 3
Frequency range Opt 106: 100 MHz – 6 GHz or Opt 115: 300 MHz – 15 GHz
Amplitude range Opt 106: autoranged to +19 dBm max (2 Vrms)
Opt 115: autoranged to +13 dBm max. (1.0 Vrms)
Sensitivity 6 GHz (Opt 106): -27 dBm (10 mVrms);
15 GHz (Opt 115): 0.3 GHz – 2 GHz: -23 dBm / 2 GHz – 13 GHz: -26 dBm / 13 GHz – 15 GHz: -21 dBm
Measurement range
Frequency resolution 10 digits/sec 12 digits/sec
Time Interval resolution NA 100 psec 20 psec
Measurements Frequency, period, frequency ratio,
max/min/peak-to-peak input voltage
Frequency, period, frequency ratio,
max/min/peak-to-peak input voltage,
time interval, single period, pulse width,
rise/fall time, duty cycle, phase, totalize
Frequency, period, frequency ratio,
max/min/peak-to-peak input voltage,
time interval, single period, pulse width,
rise/fall time, duty cycle, phase,
totalize, timestamp/MDA
Pulse/burst microwave measurements
Option 150
NA NA Carrier frequency, carrier period,
pulse repetition interval (PRI),
pulse repetition frequency (PRF),
positive and negative width
Gate characteristics
Source Time, external Time, external, advanced (gate start, stop/hold-off time or events)
Gate time (step size) 1 ms – 1000 s (10 µs) 100 µs – 1000 s (10 µs) 1 µs – 1000 s (1 µs)
Advanced: Gate start and stop hold-off NA Source: internal/external/unused standard input channel
Slope: positive/negative; delay and hold-off by time or events (edges)
Trigger characteristics
Source Internal, external, bus, manual
Trigger count and samples/trigger 1 to 1,000,000
Trigger delay 0 s to 3600 s in 1 µs steps
Math, memory, speed
Speed characteristics
(Note: Refer to pub #5990-6283EN for details
Single measurement throughput: Up to 400 readings/sec
Block Reading throughput: Up to 66,500 readings/sec
Maximum measurements to internal memory: 75,000 readings/sec frequency; 90,000 readings/sec time interval
Math Smoothing (reading moving average), scaling, ∆-change, null
Statistics Mean, standard deviation, max, min,
peak-to-peak, count
Mean, standard deviation, max, min, peak-to-peak, count, Allan Deviation
Graphical display Digits, trend, histogram, limit test, markers
Memory Volatile reading memory: 1M readings (16 MB); data log (automatically saves acquisition results to memory)
save and recall user-definable instrument set-ups; USB file system
Abbreviated Characteristics and Specifications*
So Much, So Fast www.agilent.com/fi nd/FrequencyCounters
*
Please refer to Datasheet pub #5990-6283EN for details on
specification, characteristic and typical value definitions.