Agilent Technologies Ininiium 90000 Especificações

Consulte online ou descarregue Especificações para Medição, teste e controlo Agilent Technologies Ininiium 90000. Agilent Technologies Ininiium 90000 Specifications Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 36
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
Agilent Infiniium 90000 Series Oscilloscopes
Engineered for unmatched real-time measurement accuracy
Data Sheet
Vista de página 0
1 2 3 4 5 6 ... 35 36

Resumo do Conteúdo

Página 1 - Data Sheet

Agilent Infiniium 90000 Series OscilloscopesEngineered for unmatched real-time measurement accuracyData Sheet

Página 2

10User-defined function (N5430A-1NL or Option 010 on new scope purchases) If we haven’t provided exactly what you need, use the N5430A User Defined

Página 3

11Debug your toughest designs with confidenceI2C/SPI serial trigger and decode (N5391A-1NL or Option 007 on new scope purchases) This application disp

Página 4

12SATA triggering and decode (N8801A-1NL or Option 018 on new scope purchases)Trigger on and view both protocol layer information and physical layer s

Página 5

13Pass today’s demanding compliance tests more quicklyMIPI D-phy trigger and decode (N8802A-1NL or Option 019 on new scope purchases)This application

Página 6 - Frequency Domain Analysis

14Pass today’s demanding compliance tests more quicklyEnergy Efficient Ethernet Application (N5392B-1NL or Option 060 on new scope pur-chases)Industry

Página 7 - EZJIT Complete

15Pass today’s demanding compliance tests more quicklyUSB 2.0 Compliance Test Software (N5416A-1NL or Option 029 on new scope purchases) Quickly deter

Página 8

16Pass today’s demanding compliance tests more quickly10GBASE-T Ethernet Electrical Conformance Application for Infiniium Oscilloscopes (U7236A-1NL or

Página 9

17Agilent’s Infiniium oscilloscope lineup includes bandwidths from 500 MHz to 63 GHz. Use the following selection guide to determine which best matche

Página 10

18Infiniium 90000A SeriesStarting with an 18-GHz, BNC-compatible connector, an ultra-low noise floor front end design using Faraday cage technology en

Página 11

19Install third-party software packages on Windows XP Pro operating system such as Excel, LabVIEW, Agilent VEE, MATLAB®, anti-virus software, and more

Página 12

2Why choose Agilent oscilloscopes for your toughest high-speed measurement challenges?As an engineer you’re no stranger to tough challenges that help

Página 13

20E2695A 8-GHz differential SMA probe head allows you to connect two SMA cables to make a differential measurement on a single scope channel.N5381A 13

Página 14

21E2678A 12-GHz differential socket probe head can be used to measure either differential or single‑ended signals via a plug‑on socket connection.E267

Página 15

22Infiniium 90000A Series Oscilloscopes Performance characteristicsVerticalInput channels FourAnalog bandwidth (–3 dB)*, 1090254A 90404A 90604A

Página 16

23Infiniium 90000A Series Oscilloscopes Performance characteristicsVertical (continued)RMS noise floor (scope with probe) Volts/div 20 mV 50 mV 1

Página 17 - Agilent Infiniium portfolio

24Infiniium 90000A Series Oscilloscopes Performance characteristicsAcquisitionMaximum real-time sample rate 91304A/91204A/90804A: 40 GSa/s (4 channel

Página 18 - Infiniium 90000A Series

25Infiniium 90000A Series Oscilloscopes Performance characteristicsHardware triggerSensitivity191304A/91204A/90804A: Internal low1: 2.0 div p-p 0 to

Página 19

26Infiniium 90000A Series Oscilloscopes Performance characteristicsHardware trigger (continued)Trigger modes (continued) Window VideoTriggers on an

Página 20

27Infiniium 90000A Series Oscilloscopes Performance characteristicsMeasurements and math (continued)Waveform measurements Voltage Time Mixed Freq

Página 21

28Infiniium 90000A Series Oscilloscopes Performance characteristicsMeasurements and math (continued)FFT (continued) Signal-to-noise ratio5 Window mo

Página 22 - Performance characteristics

29Infiniium 90000A Series Oscilloscopes Performance characteristicsComputer system and peripherals, I/O ports (continued)I/O ports (continued) PCI Ex

Página 23

3Engineered for unmatched real-time measurement accuracy. Use your jitter budget in your design, not on your oscilloscope.Agilent’s Infiniium 90000 Se

Página 24

30InfiniiMax II SeriesPerformance characteristics1169A, 1168ABandwidth*1169A: > 12 GHz (13 GHz typical) 1168A: > 10 GHzRise and fall time Prob

Página 25

31InfiniiMax I SeriesPerformance characteristics1134A, 1132A, 1131A, 1130ABandwidth*1134A: > 7 GHz 1131A: > 3.5 GHz1132A: > 5 GHz 1130A: &g

Página 26

32Infiniium 90000 Series ordering informationDSA Series comes with standard 50 Mpts memory, high speed serial data analysis (Option 003/E2688A), EZJIT

Página 27

33Factory installed option for new purchasesUser installed standalone product number SW applications002 E2681A-1NL EZJIT jitter analysis software (st

Página 28

34Infiniium 90000 Series ordering informationUpgrade DescriptionsN5471A DSA/DSO91204A to DSA/DSO91304A upgrade (12 GHz to 13 GHz)N5471B DSA/DSO90804A

Página 29

35Agilent Technologies OscilloscopesMultiple form factors from 20 MHz to > 90 GHz | Industry leading specs | Powerful applications

Página 30 - InfiniiMax II Series

myAgilentmyAgilentwww.agilent.com/find/myagilentA personalized view into the information most relevant to you.www.axiestandard.orgAdvancedTCA® Extensi

Página 31 - InfiniiMax I Series

4Engineered for unmatched real-time measurement accuracy.Pass today’s demanding compliance tests more quickly. Offering the industry’s widest range of

Página 32 - Presales memory options

5Engineered for unmatched real-time measurement accuracy. Debug your toughest designs with confidence.The 90000 series boasts an ever-expanding set of

Página 33

6Engineered for unmatched real-time measurement accuracy. Debug your toughest designs with confidence.Given even further insights with protocol decode

Página 34 - Operating system upgrades

7Debug your toughest designs with confidence EZJIT analysis software (E2681A-1NL or option 002 on new scope purchases) Quickly characterize and e

Página 35

8Debug your toughest designs with confidence InfiniiScan event identification (N5414B-1NL or Option 009 on new scope purchases) Rapidly trigger on

Página 36 - (BP-10-29-13)

9Debug your toughest designs with confidence Serial Data Equalization (N5461A-1NL or Option 012 on new scope purchases) Measure at the pin and use eq

Comentários a estes Manuais

Sem comentários