Agilent 86100C
Wide-Bandwidth
Oscilloscope
Technical Specifications
• Automated jitter decomposition
• Internally generated pattern trigger
• Modular platform for testing waveforms up to 40 Gb/s and beyond
• Compatible with Agilent 86100A/B-series, 83480A-series, and 54750-series modules
• 200 fs intrinsic jitter
• Open operating system – Windows
®
XP Pro
Four instruments in one
A digital communications analyzer,
a full featured wide-bandwidth oscilloscope,
a time-domain reflectometer, and a jitter analyzer
DCA-J
Vista de página 0
1 2 3 4 5 6 ... 23 24

Resumo do Conteúdo

Página 1 - Oscilloscope

Agilent 86100C Wide-BandwidthOscilloscope Technical Specifications• Automated jitter decomposition• Internally generated pattern trigger• Modular plat

Página 2 - Table of Contents

TemperatureOperating 10 °C to +40 °C (50 °F to +104 °F)Non-operating –40 °C to +65 °C (–40 °F to +158 °F)HumidityOperating Up to 90% humidity (non-con

Página 3 - Overview of infiniium DCA-J

11Mainframe specifications (continued)Standard (direct trigger) Option 001 (enhanced trigger)Trigger ModesInternal trigger1FreerunExternal direct trig

Página 4 - Eye diagram mask testing

Computer system and storageCPU 1 GHz microprocessorMass storage 40 GByte internal hard drive External USB CD-RW drive 64 MB USB pen memoryOperating Sy

Página 5 - Measurement speed

13Optical/electrical modules750-860 nmThe 86101A, 86102A and 86102U modules supportwaveform compliance testing of short wavelength signalswith up to 1

Página 6 - Utilities

1486100 family plug-In module matrixModuleOptionNo. of optical channelsNo. of electrical channelsWavelength range (nm)Unfiltered optical bandwidth (GH

Página 7

15Multimode and single-mode 86101A 86102A 86102UOPTICAL CHANNEL SPECIFICATIONSOptical channel unfiltered bandwidth 2.85 GHz (3 GHz typical) 10 GHz

Página 8

16Multimode and single-mode Optical/electrical modules 86103A 86103B 86105BOPTICAL CHANNEL SPECIFICATIONSOptical channel unfiltered bandwidth 2.85 G

Página 9 - 40 Gb/s waveforms

17High bandwidth, single-mode Optical/electrical modules 86106B 86109B 86116A186116B1OPTICAL CHANNEL SPECIFICATIONSOptical channel unfiltered bandwidt

Página 10 - Specifications

18Dual mode optical modules186111A 86111U 86113A 86115BOPTICAL CHANNEL SPECIFICATIONSOptical channel unfiltered bandwidth 2.85 GHz 15 GHz 2.85 GHz 28

Página 11 - Precision time base 86107A

19Dual electrical channel modules 86112A 54754AElectrical channel bandwidth 12.4 and 20 GHz 12.4 and 18 GHzTransition time (10% to 90%, 28.2 ps (12.4

Página 12 - Computer system and storage

Table of Contents2OverviewFeatures 340 Gb/s 9SpecificationsMainframe & triggering(includes precision time base module) 10Computer system & sto

Página 13 - Module overview

Clock recovery single mode, Multimode and electrical modules 83491A 83492A 83493A 83494AChannel type Electrical Multimode optical Single mode optical

Página 14 - Filtered data rates

21Ordering Information86100C infiniium DCA-J mainframe 86100C-001 Enhanced trigger 86100C-100 Jitter analysis software86100C-101 Advanced waveform ana

Página 15 - ±400 mV

Clock recovery modules The following modules provide a recovered clock from the data signal fortriggering at standard telecommunications and enterpris

Página 17

Agilent Technologies’ Test and MeasurementSupport, Services, and AssistanceAgilent Technologies aims to maximize the valueyou receive, while minimizin

Página 18 - (referenced two

3Windows is a U.S. registered trademark of Microsoft Corporation.FeaturesPatternLock TriggeringThe Enhanced Trigger Option (Option 001) on the 86100Cp

Página 19

4Option 101 requires Option 100 and adds additionalcapability:• Periodic jitter frequency• Isolation and analysis of Sub-Rate Jitter (SRJ), that is, p

Página 20 - TDR system

5Eyeline ModeEyeline Mode is a new feature only available in the86100C that provides insight into the effects of specificbit transitions within a data

Página 21 - Ordering Information

6Standard FunctionsStandard functions are available through pull downmenus and soft keys, and some functions are alsoaccessible through the front pane

Página 22

7Built-in information systemThe 86100C has a context-sensitive on-line manual providing immediate answers to your questions about using the instrument

Página 23

Waveform autoscalingAutoscaling provides quick horizontal and vertical scalingof both pulse and eye-diagram (RZ and NRZ) waveforms.Time domain reflect

Página 24

Lowest intrinsic jitterThe patented 86107A precisiontimebase reference module representsone of the most significantimprovements in wide-bandwidthsampl